Stator winding turn-fault detection for closed-loop induction motor drives
- 28 May 2003
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 39 (3) , 720-724
- https://doi.org/10.1109/tia.2003.811784
Abstract
Sensorless diagnostics for line-connected machines is based on extracting fault signatures from the spectrum of the line currents. However, for closed-loop drives, the power supply is a regulated current source and, hence, the motor voltages must also be monitored for fault information. In this paper, a previously proposed neural network scheme for turn-fault detection in line-connected induction machines is extended to inverter-fed machines, with special emphasis on closed-loop drives. Experimental results are provided to illustrate that the method is impervious to machine and instrumentation nonidealities, and that it requires lesser data memory and computation requirements than existing schemes, which are based on data lookup tables.Keywords
This publication has 7 references indexed in Scilit:
- A new approach to on-line turn fault detection in AC motorsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Insulation failure detection in the stator windings of ASD-driven induction machines using standard deviation of line currentsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Continual on-line training of neural networks with applications to electric machine fault diagnosticsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Neural network based on-line stator winding turn fault detection for induction motorsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2002
- Transient model for induction machines with stator winding turn faultsIEEE Transactions on Industry Applications, 2002
- On-line stator winding faults detection in inverter fed induction motors by stator current reconstructionPublished by Institution of Engineering and Technology (IET) ,1999
- Analysis of Cage Induction Motors with Stator Winding FaultsIEEE Transactions on Power Apparatus and Systems, 1985