Quad-Detector Arrangement and Sampling Characteristics in Rotary Positron Tomography: POSITOLOGICA II
- 1 October 1982
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 1 (2) , 136-142
- https://doi.org/10.1109/tmi.1982.4307560
Abstract
This paper clarifies that a method of rotary positron-emission computed tomography (PCT) with quad (tri or bi)-detector units can provide the satisfactory sampling characteristics with negligible sacrifice (less than 1 percent) of the detector packing ratio. This paper also presents the array design of quad-BGO (bismuth germanate) units and the sampling characteristics of a rotary PCT system named POSITOLOGICA II. In the rotary PCT, detector units are mounted unequally spaced on a ring so as to provide fine and uniform linear sampling during a 360° rotation of the ring around its center. This principle was applied to a system named POSITOLOGICA I, but it has unidetector units [one detector-one photomultiplier tube (PMT)]. The quad-detector unit consists of four BGO crystals, two PMT's, and a circuit positioning the address of the crystal by which a gamma ray is detected. Merits of the quad units are an effective coupling between rectangular crystals and a photocathode of PMT and reduction of the number of PMT's.Keywords
This publication has 26 references indexed in Scilit:
- Electronics syteem for positron computerized tomography “positologica” dedicated to head studiesNuclear Instruments and Methods in Physics Research, 1982
- A quad BGO detector and its timing and positioning discrimination for positron computed tomographyNuclear Instruments and Methods in Physics Research, 1982
- PETT VIJournal of Computer Assisted Tomography, 1982
- Sampling Properties of Stationary and Half-Rotation Rings in Positron Emission TomographyJournal of Computer Assisted Tomography, 1981
- HEADTOMEJournal of Computer Assisted Tomography, 1981
- AliasingJournal of Computer Assisted Tomography, 1979
- Data Collection for Cross-Sectional Image Reconstruction by a Moving Ring of Positron Annihilation DetectorsJournal of Computer Assisted Tomography, 1979
- The effects of a finite number of projection angles and finite lateral sampling of projections on the propagation of statistical errors in transverse section reconstructionPhysics in Medicine & Biology, 1977
- Emission Computer Assisted Tomography with Single-Photon and Positron Annihilation Photon EmittersJournal of Computer Assisted Tomography, 1977