A new rapid point-of-care D-dimer enzyme-linked immunosorbent assay (Stratus CS D-dimer) for the exclusion of venous thromboembolism
- 1 July 2004
- journal article
- research article
- Published by Wolters Kluwer Health in Blood Coagulation & Fibrinolysis
- Vol. 15 (5) , 435-438
- https://doi.org/10.1097/01.mbc.0000114443.59147.c4
Abstract
To evaluate the performances of a new D-dimer assay, Stratus CS D-dimer (Dade Behring, Newark, Delaware, USA), for the exclusion of venous thromboembolism and to determine the best cut-off values. This test relies on a sandwich enzyme-linked immunosorbent assay with a fluorogenic substrate in a radial partition immunoassay system in a dedicated device. It does not require laboratory staff and the results are available within 18 min. Two hundred and ninety-one frozen samples from patients suspected of either deep venous thrombosis (n = 137) or pulmonary embolism (n = 154) were measured and the results compared with the VIDAS D-dimer New assay. There were 37 deep venous thrombosis (27%) and 49 pulmonary embolism (32%) samples. Receiver–operating characteristic curve analysis indicated that the cut-off value could be set at either 300 or 400 ng/ml Fibrinogen Equivalent Units (FEU). The coefficient of variation determined with a lyophilized low-level control plasma (305 ng/ml FEU) was 6%. With a cut-off at 300 ng/ml FEU, the sensitivity, the specificity and the negative predictive value were 100% [95% confidence interval (CI), 95.8–100], 33.1% (95% CI, 26.8–40) and 100% (95% CI, 94.7–100), respectively. Raising the cut-off to 400 ng/ml FEU, the corresponding figures were 96.5% (95% CI, 90.1–99.3), 46.3% (95% CI, 39.4–53.2) and 96.9% (95% CI, 91.3–99.4), respectively. At 400 ng/ml, three results were false-negative, one with both devices and two with the Stratus D-dimer only. Stratus D-dimer appears to be suitable for the exclusion of venous thromboembolism in the emergency room setting.Keywords
This publication has 15 references indexed in Scilit:
- Limited interobserver agreement in the SimpliRED d-dimer assayJournal of Thrombosis and Haemostasis, 2003
- Evaluation of Advanced D-dimer assay for the exclusion of venous thromboembolismThrombosis Research, 2002
- The accuracy of the enzyme-linked immunosorbent assay D -dimer test in the diagnosis of pulmonary embolism: A meta-analysisAnnals of Emergency Medicine, 2002
- Multicentre evaluation of a new point-of-care test for the quantitative determination of D-dimerClinica Chimica Acta; International Journal of Clinical Chemistry, 2001
- Performances of the VIDAS D-dimer New Assay for the Exclusion of Venous ThromboembolismThrombosis and Haemostasis, 2001
- Use of D-Dimer Assays in the Diagnosis of Venous ThrombosisSeminars in Thrombosis and Hemostasis, 2000
- Diagnostic Value of the Nycocard®, Nycomed® D-Dimer Assay for the Diagnosis of Deep Venous Thrombosis and Pulmonary Embolism: A Retrospective StudyThrombosis Research, 2000
- Non-invasive diagnosis of venous thromboembolism in outpatientsThe Lancet, 1999
- D-dimer Strategy in Thrombosis ExclusionThrombosis and Haemostasis, 1998
- The detection of d-dimer in plasma by enzyme immunoassayBlood Coagulation & Fibrinolysis, 1994