Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at l.5T preliminary results
- 1 September 1993
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 30 (3) , 387-392
- https://doi.org/10.1002/mrm.1910300318
Abstract
We have measured the T2* signal response associated with cortical activation due to finger motion at 1.5 Tesla. Both thin slice 2D and 3D images show signal intensity changes which vary from 2% to 32% depending on volunteer, echo time, slice thickness, and in-plane resolution. The largest signal change occurred for the thinnest slices and highest resolution (2 mm3). This is consistent with reducing partial volume effects and a simple difference in phase between the intravascular signal and surrounding parenchyma. No inflow enhancement was seen on the 2D or 3D scans, confirming the nature of the signal difference for this approach was due to local field in-homogeneity effects. Using 3D imaging, multiple effects can be seen simultaneously. With a 3D MRA method, it was possible to locate the vessel that was the source of the T2* behavior; it was in each case a vein on the surface of the cortical parenchyma.Keywords
This publication has 11 references indexed in Scilit:
- Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPIMagnetic Resonance in Medicine, 1993
- Functional MRI of human brain activation at high spatial resolutionMagnetic Resonance in Medicine, 1993
- Basic physics of MR contrast agents and maximization of image contrastJournal of Magnetic Resonance Imaging, 1993
- Dynamic MR imaging of human brain oxygenation during rest and photic stimulationJournal of Magnetic Resonance Imaging, 1992
- Dynamic magnetic resonance imaging of human brain activity during primary sensory stimulation.Proceedings of the National Academy of Sciences, 1992
- Oxygenation‐sensitive contrast in magnetic resonance image of rodent brain at high magnetic fieldsMagnetic Resonance in Medicine, 1990
- Reduction of T2* dephasing in gradient field-echo imaging.Radiology, 1989
- Nonoxidative Glucose Consumption During Focal Physiologic Neural ActivityScience, 1988
- Identification of Cortical Sulci and Gyri Using Magnetic Resonance Imaging: a Preliminary StudyPublished by Springer Nature ,1988
- A STRUCTURAL INTERPRETATION OF THE ACIDITY OF GROUPS ASSOCIATED WITH THE HEMES OF HEMOGLOBIN AND HEMOGLOBIN DERIVATIVESJournal of Biological Chemistry, 1940