Immobilized Glucose Oxidase in the Potentiometric Detection of Glucose
- 1 February 1984
- journal article
- Published by Springer Nature in Applied Biochemistry and Biotechnology
- Vol. 9 (1) , 95-104
- https://doi.org/10.1007/bf02798377
Abstract
Previous work has shown that glucose oxidase can be immobilized on platinum to give an electrode that responds potentiometrically to glucose over the clinically useful range of about 10–250 mg glucose/100 mL. The present studies were carried out with electrochemically pretreated platinum and with gold or porous graphite substituted for the platinum support. The presence of the enzyme gave a significantly enhanced potentiometric response over that obtained with the bare support for both the pretreated platinum and the porous graphite, but not with gold. However, with platinum the potentiometric response became more negative with increasing glucose concentration. With porous graphite, the potential changed in the positive direction as the glucose concentration was increased. Hysteresis was demonstrated for the platinum-enzyme electrode. Mass transfer measurements with a rotating ring-disc electrode (RRDE) showed measurable diffusional resistances to the transport of a model electroactive compound (potassium ferrocyanide) through a matrix of immobilized enzyme attached to the disc of the RRDE. These results are part of a larger study to define the source of the potentiometric response by examining the roles of the support and the mass transfer resistances through the immobilized enzyme matrix.Keywords
This publication has 10 references indexed in Scilit:
- Implanting the Glucose Enzyme Electrode: Problems, Progress, and Alternative SolutionsDiabetes Care, 1982
- Direct coupling of glucose oxidase to platinum and possible use forin vivo glucose determinationJournal of Solid-Phase Biochemistry, 1979
- Immobilized enzyme electrodes for the potentiometric measurement of glucose concentration: Immobilization techniques and materialsJournal of Biomedical Materials Research, 1979
- 262 - Quantitation of glucose concentration using a glucose oxidase-catalase electrode by potentiometric measurementBioelectrochemistry and Bioenergetics, 1979
- Chemically modified electrodes. 13. Monolayer/multilayer coverage, decay kinetics, and solvent and interaction effects for ferrocenes covalently linked to platinum electrodesJournal of the American Chemical Society, 1978
- Chemically modified carbon electrodesAnalytical Chemistry, 1976
- The real condition of electrochemically oxidized platinum surfacesJournal of Electroanalytical Chemistry and Interfacial Electrochemistry, 1973
- Electrochemical measurements with glucose oxidase immobilized in polyacrylamide gel: Constant current voltametryBiotechnology & Bioengineering, 1971