A Monte Carlo investigation of dual-energy-window scatter correction for volume-of-interest quantification in99TcmSPECT
- 1 January 1995
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 40 (1) , 181-199
- https://doi.org/10.1088/0031-9155/40/1/015
Abstract
Using Monte Carlo simulation of 99Tcm single-photon-emission computed tomography (SPECT), we investigate the effects of tissue-background activity, tumour location, patient size, uncertainty of energy windows, and definition of tumour region on the accuracy of quantification. The dual-energy-window method of correction for Compton scattering is employed and the multiplier which yields correct activity for the VI as a whole calculated. The model is usually a sphere containing radioactive water located within a cylinder filled with a more dilute solution of radioactivity. Two simulation codes are employed. Reconstruction is by ML-EM algorithm with attenuation compensation. The scatter multiplier depends only slightly on the sphere location or the cylinder diameter. It also depends little on whether correction is before or after reconstruction. At low background level, it changes with VOI size, but not at higher background. For a geometrical VOI, it is 1.25 at zero background, decreases sharply to 0.56 for equal concentrations, and is 0.44 when the background concentration is very large. Quantification is accurate (less than 9% error) if the test background is reasonably close to that used in setting the universal scatter-multiplier value, or if the test backgrounds are always large and so is the universal-value background, but not if the test backgrounds cover a large range of values including zero. Results largely agree with those from experiment after the experimental data with background is re-evaluated with prejudice.Keywords
This publication has 11 references indexed in Scilit:
- A regularized deconvolution-fitting method for Compton-scatter correction in SPECTIEEE Transactions on Medical Imaging, 1992
- A practical method for position-dependent Compton-scatter correction in single photon emission CTIEEE Transactions on Medical Imaging, 1991
- Monte Carlo techniques in medical radiation physicsPhysics in Medicine & Biology, 1991
- Improved quantification of radionuclide uptake using deconvolution and windowed subtraction techniques for scatter compensation in single photon emission computed tomographyMedical Physics, 1990
- Comparison of dual-window and convolution scatter correction techniques using the Monte Carlo methodPhysics in Medicine & Biology, 1990
- A Monte Carlo program for the simulation of scintillation camera characteristicsComputer Methods and Programs in Biomedicine, 1989
- Introduction to holospectral imaging in nuclear medicine for scatter subtractionIEEE Transactions on Medical Imaging, 1989
- An attenuated projector-backprojector for iterative SPECT reconstructionPhysics in Medicine & Biology, 1985
- Energy and spatial distribution of multiple order Compton scatter in SPECT: a Monte Carlo investigationPhysics in Medicine & Biology, 1984