Overcoming Compound Interference in Fluorescence Polarization-Based Kinase Assays Using Far-Red Tracers
- 1 April 2004
- journal article
- Published by Mary Ann Liebert Inc in ASSAY and Drug Development Technologies
- Vol. 2 (2) , 193-203
- https://doi.org/10.1089/154065804323056530
Abstract
Kinase-mediated phosphorylation of proteins is critical to the regulation of many biological processes, including cell growth, apoptosis, and differentiation. Because of the central role that kinases play in processes that can lead to disease states, the targeting of kinases with small-molecule inhibitors is a validated strategy for therapeutic intervention. Classic methods for assaying kinases include nonhomogenous enzyme-linked immunosorbent assays or scintillation-based formats using [gamma-(32)P]ATP. However, homogenous fluorescence-based assays have gained in popularity in recent years due to decreased costs in reagent usage through miniaturization, increased throughput, and avoidance of regulatory costs associated with the use of radiation. Whereas the readout signal from a nonhomogenous or radioactive assay is largely impervious to interferences from matrix components (such as library compounds), all homogenous fluorescent assay formats are subject to such interferences. Interference from intrinsically fluorescent compounds or from scattered light due to precipitated compounds can interfere with assays that depend on a fluorescence intensity (or fluorescence quenching), fluorescence resonance energy transfer, or fluorescence polarization-based readout. Because these interfering factors show a greater effect at lower wavelengths, one strategy to overcome such interferences is to develop fluorescent assays using longer wavelength (red-shifted) fluorescent probes. In this article, we describe the PanVera PolarScreen far-red fluorescence polarization assay format, which mitigates assay interference from autofluorescent compounds or scattered light through the use of a far-red tracer. The tracer shows substantially less interference from light scatter or autofluorescent library compounds than do fluorescein-based tracers, and gives rise to a larger assay window than the popular far-red fluorophore Cy5.Keywords
This publication has 16 references indexed in Scilit:
- Use of Red-Shifted Dyes in a Fluorescence Polarization AKT Kinase Assay for Detection of Biological Activity in Natural Product ExtractsSLAS Discovery, 2004
- Miniaturization of Fluorescence Polarization Receptor-Binding Assays Using CyDye-Labeled LigandsSLAS Discovery, 2003
- Fluorescence Polarization Competition Assay: The Range of Resolvable Inhibitor Potency Is Limited by the Affinity of the Fluorescent LigandSLAS Discovery, 2003
- Homogeneous fluorescence readouts for miniaturized high-throughput screening: theory and practiceDrug Discovery Today, 1999
- A Simple Statistical Parameter for Use in Evaluation and Validation of High Throughput Screening AssaysSLAS Discovery, 1999
- Screen Compounds Singly: Why Muck It Up?SLAS Discovery, 1998
- Screening of Compound Libraries... Consommé or Gumbo?SLAS Discovery, 1998
- Inhibition of glycogen synthase kinase-3 by insulin mediated by protein kinase BNature, 1995
- Fluorescence polarization — a new tool for cell and molecular biologyNature, 1995
- Fluorescence Polarization Immunoassay for the Determination of Therapeutic Drug Levels in Human PlasmaJournal of Analytical Toxicology, 1981