An Evaluation of Commercial Fluorescent Bead-Based Luminex Cytokine Assays
Open Access
- 2 July 2008
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 3 (7) , e2535
- https://doi.org/10.1371/journal.pone.0002535
Abstract
The recent introduction of fluorescent bead-based technology, allowing the measurement of multiples analytes in a single 25–50 µl sample has revolutionized the study of cytokine responses. However, such multiplex approaches may compromise the ability of these assays to accurately measure actual cytokine levels. This study evaluates the performance of three commercially available multiplex cytokine fluorescent bead-based immunoassays (Bio-Rad's Cytokine 17-plex kit; LINCO Inc's 29-plex kit; and RnD System's Fluorokine-Multi Analyte Profiling (MAP) base kit A and B). The LINCO Inc kit was found to be the most sensitive assay for measuring concentrations of multiple recombinant cytokines in samples that had been spiked with serial dilutions of the standard provided by the manufacturer, followed respectively by the RnD Fluorokine-(MAP) and Bio-Rad 17-plex kits. A positive correlation was found in the levels of IFN-γ measured in antigen stimulated whole blood culture supernatants by the LINCO Inc 29-plex, RnD Fluorokine-(MAP) and RnD system IFN-γ Quantikine ELISA kits across a panel of controls and stimulated samples. Researchers should take the limitation of such multiplexed assays into account when planning experiments and the most appropriate use for these tests may currently be as screening tools for the selection of promising markers for analysis by more sensitive techniques.Keywords
This publication has 21 references indexed in Scilit:
- Circulating Inflammatory Cytokine Expression in Men With Prostate Cancer Undergoing Androgen Deprivation TherapyJournal of Andrology, 2006
- Solid-phase and bead-based cytokine immunoassay: A comparisonMethods, 2006
- Nutritional Status and Serum Cytokine Profiles in Children, Adolescents, and Young Adults withSchistosoma japonicum–Associated Hepatic Fibrosis, in Leyte, PhilippinesThe Journal of Infectious Diseases, 2005
- Multiplex bead array assays for detection of soluble cytokines: Comparisons of sensitivity and quantitative values among kits from multiple manufacturersCytometry Part B: Clinical Cytometry, 2004
- Heterophile Antibody Interference in a Multiplexed Fluorescent Microsphere Immunoassay for Quantitation of Cytokines in Human SerumClinical and Vaccine Immunology, 2004
- Cytokines as Mediators for or Effectors against Rotavirus Disease in ChildrenClinical and Vaccine Immunology, 2003
- Bead-Based Multiplex Analysis/Bead-basierte MultiplexanalyseJournal of Laboratory Medicine, 2003
- Simultaneous Quantitation of Antibodies to Neutralizing Epitopes on Virus-Like Particles for Human Papillomavirus Types 6, 11, 16, and 18 by a Multiplexed Luminex AssayClinical and Vaccine Immunology, 2003
- Multiplex analysis of cytokines in the blood of cynomolgus macaques naturally infected with Ebola virus (reston serotype)**Journal of Medical Virology, 2001
- Change of Th0 to Th1 Cell-Cytokine Profile Following Tuberculosis ChemotherapyScandinavian Journal of Immunology, 2000