Analysis for Exhaust Gas Hydrocarbons—Nondispersive Infrared Versus Flame-lonizaticn
Open Access
- 1 December 1966
- journal article
- research article
- Published by Taylor & Francis in Journal of the Air Pollution Control Association
- Vol. 16 (12) , 697-702
- https://doi.org/10.1080/00022470.1966.10468536
Abstract
An investigation has been made of the suitability of a nondispersive infrared analyzer and two flame-ionization analyzers for measuring the total hydrocarbon concentrations of automobile exhaust gas. The investigation consisted of measuring relative responses of various hydrocarbons, checking for possible exhaust gas interferences and finally comparing exhaust hydrocarbon concentrations indicated by the flame-ionization analyzer to those indicated by the infrared analyzer. The infrared analyzer has high relative responses for parraffins and low responses for olefins, acetylenes, and aromatics. Also, the infrared indicated hydrocarbon concentrations must be corrected for exhaust water vapor interference. When the flameionization analyzers are operated at conditions that result in approximately uniform response to hydrocarbons and low oxygen interference, the exhaust hydrocarbon concentrations indicated by either flameionization analyzer are better approximations of the total hydrocarbon concentration than those indicated by the infrared analyzer.Keywords
This publication has 0 references indexed in Scilit: