The magic angle phenomenon in tendons: effect of varying the MR echo time.
- 1 January 1998
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 71 (841) , 31-36
- https://doi.org/10.1259/bjr.71.841.9534696
Abstract
Increased signal intensity on magnetic resonance (MR) imaging of tendons arising from the magic angle phenomenon is well recognized. This study aimed to evaluate the effect of varying the echo time (TE) upon tendon signal intensity, and to determine if a modified TE value produces acceptable T1 and proton density (PD) weighted images. Fresh bovine tendons were imaged in a 1.5 T MR scanner using spin echo (SE) T1 and PD weighted sequences and utilizing a number of different coils. For each set of sequences, the tendon was orientated at 55 degrees to the main magnetic field (B0) and imaged using constant TR and incremental TE values. Signal intensity was measured on images at each TR/TE value and compared with the signal intensities of tendons orientated at 0 degree to B0, obtained using minimum TE values. This experiment was repeated with a 1.0 T MR scanner and utilizing a spine coil. The Achilles tendon of a human volunteer was similarly imaged using a general purpose flex coil. For bovine and human tendons orientated at 55 degrees to B0, the signal intensities decreased exponentially with increasing TE. A critical TE value exceeding 37 ms, for each sequence, reduced the signal intensities to the levels obtained with the tendons orientated at 0 degree to B0, such that the magic angle phenomenon could be avoided. Although there was variability of the signal intensities with different coils, the critical TE value remained constant and the anatomical clarity was not degraded. The critical TE value was unaltered using two MR scanners of different field strengths.Keywords
This publication has 9 references indexed in Scilit:
- RECENT ADVANCES IN MAGNETIC RESONANCE IMAGING OF THE MUSCULOSKELETAL SYSTEMRadiologic Clinics of North America, 2022
- Increased signal in the normal supraspinatus tendon on MR imaging: diagnostic pitfall caused by the magic-angle effect.American Journal of Roentgenology, 1995
- Rotator cuff disorders: interobserver and intraobserver variation in diagnosis with MR imaging.Radiology, 1995
- "Magic-angle" phenomenon: a cause of increased signal in the normal lateral meniscus on short-TE MR images of the knee.American Journal of Roentgenology, 1994
- Effects of collagen orientation on MR imaging characteristics of bovine articular cartilage.Radiology, 1993
- The "magic angle" effect: background physics and clinical relevance.Radiology, 1993
- Alterations in the supraspinatus tendon at MR imaging: correlation with histopathologic findings in cadavers.Radiology, 1991
- Effect of tendon orientation on MR imaging signal intensity: a manifestation of the "magic angle" phenomenon.Radiology, 1991
- Orientation of tendons in the magnetic field and its effect on T2 relaxation times.Radiology, 1985