A New Atrial Lead with Improved Stability and P‐Wave Detection
- 1 May 1983
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 6 (3) , 726-734
- https://doi.org/10.1111/j.1540-8159.1983.tb05333.x
Abstract
A new segmented polyether polyurethane atrial pacemaker lead has been developed and tested acutely and chronically in dogs. This lead was constructed so that its tip could quickly and accurately be positioned in close proximity to the S-A node and provide long-term stability without the use of active fixation devices such as tines or screws. The acute intrinsic P-wave potentials seen at the S-A node area (9.7 +/- 4.7 mV) were superior to those detected in the appendage (4.7 +/- 2.8 mV) and coronary sinus (6.8 +/- 4.1 mV). There were no significant differences in pacing thresholds between sites. In long-term studies, transvenous (jugular) leads maintained their position for over three months without dislodgment in active unrestrained dogs with only a 25% decrease in intrinsic P-wave potentials. The chronic pacing thresholds for this lead were similar, or superior, to those reported for other pacemaker lead placement sites. The polyurethane coating material produces no adverse tissue reaction or thrombosis.Keywords
This publication has 18 references indexed in Scilit:
- Malfunction of a Sheath‐Retracting Active‐Fixation Pacemaker Electrode Due to Impacted EndocardiumPacing and Clinical Electrophysiology, 1982
- Clinical Experience with Permanent Atrioventricular Sequential PacingThe Annals of Thoracic Surgery, 1981
- Three‐Year Clinical Experience with a New Endocardial Screw‐In Lead with Introduction Protection for Use in the Atrium and VentriclePacing and Clinical Electrophysiology, 1980
- A New Lead for Transvenous Atrial Pacing and Sensing Clinical and Electrophysiological ExperiencesPacing and Clinical Electrophysiology, 1980
- Atrial PacingPacing and Clinical Electrophysiology, 1980
- Multicentric origin of the atrial depolarization wave: the pacemaker complex. Relation to dynamics of atrial conduction, P-wave changes and heart rate control.Circulation, 1978
- Coronary sinus pacing clinical follow-up.Circulation, 1978
- Cardiac pacing and pacemakers IV. Threshold of cardiac stimulationAmerican Heart Journal, 1977
- Effect of stimulation site on ventricular threshold in dogs with heart blockAmerican Heart Journal, 1975
- Changes in myocardial threshold. Physiologic and pharmacologic factors in patients with implanted pacemakersAmerican Heart Journal, 1967