The Effects of Scaling a Titanium Implant Surface With Metal and Plastic Instruments: An in Vitro Study
- 1 August 1990
- journal article
- research article
- Published by Wiley in The Journal of Periodontology
- Vol. 61 (8) , 485-490
- https://doi.org/10.1902/jop.1990.61.8.485
Abstract
The surface roughnesses of pure titanium implants were compared after scaling in vitro with curettes of dissimilar composition. Each of 10 transmucosal implant extensions (TIEs) was divided into three experimental surfaces and an untreated control surface. The three experimental surfaces were instrumented with either a titanium-alloy tipped curette, a curette of stainless steel, or a plastic curette. All experimental surfaces received 30 strokes with the designated curette within a 2 mm wide area. Alteration of the surfaces due to instrumentation was evaluated by a helium neon (HeNe) laser and reported as relative specular reflectance (RSR). Scanning electron microscopy (SEM) confirmed the quantitative HeNe laser results. A significant decrease in mean RSR (greater roughness) was observed for surfaces treated by metal curettes compared to either untreated control surfaces (P < 0.01) or surfaces treated by plastic curette (P < 0.01). No statistically significant difference was noted between untreated surfaces and those treated by the plastic curette. The titanium-alloy curette produced a significantly lower mean RSR (greater roughness) compared to those surfaces treated by the stainless steel curette (P < 0.05). In summary, plastic instruments produced an insignificant alteration of the titanium implant surface following instrumentation, while metal instruments significantly altered the titanium surface.This publication has 13 references indexed in Scilit:
- Surface roughness of stainless steel and electroformed nickel standards using a HeNe laserOptics & Laser Technology, 1987
- Migration, Attachment, and Orientation of Human Gingival Fibroblasts to Root Slices, Naked and Porous-surfaced Titanium Alloy Discs, and Zircalloy 2 Discs in vitroJournal of Dental Research, 1987
- A clinical evaluation of fixed‐bridge restorations supported by the combination of teeth and osseointegrated titanium implantsJournal of Clinical Periodontology, 1986
- Evidence for a Junctional Epithelial Attachment to Ceramic Dental ImplantsThe Journal of Periodontology, 1985
- Titanium: The mystery metal of implant dentistry. Dental materials aspectsThe Journal of Prosthetic Dentistry, 1985
- Biocompatibility of titanium implants: Surface science aspectsThe Journal of Prosthetic Dentistry, 1983
- The attachment mechanism of epithelial cells to titanium in vitroJournal of Periodontal Research, 1981
- Optical techniques for on-line measurement of surface topographyPrecision Engineering, 1981
- The reactions of bone, connective tissue, and epithelium to endosteal implants with titanium-sprayed surfacesJournal of Maxillofacial Surgery, 1981