Ambulatory Blood Pressure Monitoring Is Associated With Reduced Physical Activity During Everyday Life
- 1 November 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Psychosomatic Medicine
- Vol. 61 (6) , 806-811
- https://doi.org/10.1097/00006842-199911000-00013
Abstract
The objective of this study was to assess the impact on noninvasive ambulatory blood pressure monitoring on physical activity measured objectively by use of triaxial accelerometers. Twenty-four working men and women performed ambulatory blood pressure plus activity monitoring for 1 working day and evening and activity monitoring alone for a separate day and evening. Blood pressure measures were taken at 20-minute intervals during the day and 30-minute intervals in the evening and were accompanied by diary assessments of mood, location, and posture. Comparisons were made of energy expenditure on the 2 days and of activity levels during the minutes surrounding each blood pressure reading and diary completion. Energy expenditure assessed in terms of activity calories per hour was significantly lower during blood pressure plus activity monitoring compared with activity monitoring alone (mean 37.3, SD = 16.3 vs. mean = 43.0, SD = 18.7 kcal, respectively: p= .02). Energy expenditure was lower during the 4 minutes surrounding each blood pressure reading than in the intervals between blood pressure readings. However, energy expenditure was also lower in the intervals between blood pressure readings than during comparable times on the activity only monitoring day. Blood pressure, heart rate, and physical activity were moderately correlated within individuals. Ambulatory blood pressure recording using automated sphygmomanometers is associated with reduced physical activity during the monitoring day. This is due partly to regular periods of immobility during cuff inflation and deflation and diary completion and partly to more general self-imposed restrictions on activity. This pattern has implications for the representativeness of ambulatory blood pressure monitoring, and the construction of ambulatory monitoring diaries.Keywords
This publication has 19 references indexed in Scilit:
- Job strain, blood pressure and response to uncontrollable stressJournal Of Hypertension, 1999
- The Validity of the Tritrac-R3D Activity Monitor for the Assessment of Physical Activity: II. Temporal Relationships among Objective AssessmentsResearch Quarterly for Exercise and Sport, 1998
- A Longitudinal Study of Job Strain and Ambulatory Blood PressurePsychosomatic Medicine, 1998
- Effects of task strain, social conflict, and emotional activation on ambulatory cardiovascular activity: Daily life consequences of recurring stress in a multiethnic adult sample.Health Psychology, 1998
- Evaluation of a Commercial Accelerometer (Tritrac-R3 D) to Measure Energy Expenditure During AmbulationInternational Journal of Sports Medicine, 1998
- Social support and hostility interact to influence clinic, work, and home blood pressure in Black and White men and womenPsychophysiology, 1996
- Comparative accuracy of six ambulatory devices according to blood pressure levelsJournal Of Hypertension, 1993
- Methodological problems in evaluation of cardiovascular effects of stress in humans.Hypertension, 1991
- Posture, Place, and Mood Effects on Ambulatory Blood PressurePsychophysiology, 1990
- Effects of 24-hour ambulatory blood pressure monitoring on daily activities.Health Psychology, 1990