Accounting for beta‐particle energy loss to cortical bone via paired‐image radiation transport (PIRT)
- 18 April 2005
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 32 (5) , 1354-1366
- https://doi.org/10.1118/1.1898463
Abstract
Current methods of skeletal dose assessment in both medical physics (radionuclide therapy) and health physics (dose reconstruction and risk assessment) rely heavily on a single set of bone and marrow cavity chord-length distributions in which particle energy deposition is tracked within an infinite extent of trabecular spongiosa, with no allowance for particle escape to cortical bone. In the present study, we introduce a paired-image radiation transport (PIRT) model which provides a more realistic three-dimensional (3D) geometry for particle transport in the skeletal site at both microscopic and macroscopic levels of its histology. Ex vivo CT scans were acquired of the pelvis, cranial cap, and individual ribs excised from a 66-year male cadaver (BMI of 22.7 kg m(-2)). For the three skeletal sites, regions of trabecular spongiosa and cortical bone were identified and segmented. Physical sections of interior spongiosa were taken and subjected to microCT imaging. Voxels within the resulting microCT images were then segmented and labeled as regions of bone trabeculae, endosteum, active marrow, and inactive marrow through application of image processing algorithms. The PIRT methodology was then implemented within the EGSNRC radiation transport code whereby electrons of various initial energies are simultaneously tracked within both the ex vivo CT macroimage and the CT microimage of the skeletal site. At initial electron energies greater than 50-200 keV, a divergence in absorbed fractions to active marrow are noted between PIRT model simulations and those estimated under existing techniques of infinite spongiosa transport. Calculations of radionuclide S values under both methodologies imply that current chord-based models may overestimate the absorbed dose to active bone marrow in these skeletal sites by 0% to 27% for low-energy beta emitters (33P, 169Er, and 177Lu), by approximately 4% to 49% for intermediate-energy beta emitters (153Sm, 186Re, and 89Sr), and by approximately 14% to 76% for high-energy beta emitters (32p, 188Re, and 90Y). The PIRT methodology allows for detailed modeling of the 3D macrostructure of individual marrow-containing bones within the skeleton thus permitting improved estimates of absorbed fractions and radionuclide S values for intermediate-to-high energy beta emitters.Keywords
Funding Information
- U.S. Department of Energy (CA96441)
- U.S. Department of Energy (DE‐FG07‐02ID14327)
This publication has 9 references indexed in Scilit:
- Considerations of anthropometric, tissue volume, and tissue mass scaling for improved patient specificity of skeletal S valuesMedical Physics, 2002
- SKELETAL DOSIMETRY VIA NMR MICROSCOPY: INVESTIGATIONS OF SAMPLE REPRODUCIBILITY AND SIGNAL SOURCEHealth Physics, 2002
- Site‐specific variability in trabecular bone dosimetry: Considerations of energy loss to cortical boneMedical Physics, 2001
- Beta‐particle dosimetry of the trabecular skeleton using Monte Carlo transport within 3D digital imagesMedical Physics, 2001
- Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 versionMedical Physics, 2000
- Electron Absorbed Fractions and Dose Conversion Factors for Marrow and Bone by Skeletal RegionsHealth Physics, 2000
- NMR Microscopy of Trabecular Bone and its Role in Skeletal DosimetryHealth Physics, 1998
- A Microtomographic System for the Nondestructive Evaluation of Bone ArchitectureCalcified Tissue International, 1996
- Availability of Nuclear Decay Data in Electronic Form, Including Beta Spectra Not Previously PublishedHealth Physics, 1994