Hydrodynamic Function of a Biostable Polyurethane Flexible Heart Valve after Six Months in Sheep
- 1 February 2001
- journal article
- research article
- Published by SAGE Publications in The International Journal of Artificial Organs
- Vol. 24 (2) , 95-101
- https://doi.org/10.1177/039139880102400207
Abstract
Survival to six months for sheep with a non-biostable polyurethane mitral heart valve prosthesis has been reported previously, however, with surface degradation and accumulation of calcified fibrin/thrombus that impaired leaflet motion and compromised hydrodynamic function. Newly available biostable polyurethanes may overcome this problem. Six adult sheep with biostable polyurethane trileaflet heart valve prostheses of documented hydrodynamic performance, implanted in the mitral position, were allowed to survive for 6 months. Explanted valves were photographed, resubmitted to hydrodynamic function testing, and studied by light and electron microscopy. Explanted valves were structurally intact and differed little in appearance from their preimplant state. Hydrodynamic testing showed no deterioration in pressure gradient or energy losses compared with pre-implant values. Biostable polyurethanes demonstrated improved blood compatibility leaving leaflets flexible and valve function unimpaired. Biostable polyurethanes may thus improve prospects for prolonged function of synthetic heart valve prostheses.Keywords
This publication has 16 references indexed in Scilit:
- Polyurethane: material for the next generation of heart valve prostheses?European Journal of Cardio-Thoracic Surgery, 2000
- Biomedical Applications of Polyurethanes: A Review of Past Promises, Present Realities, and a Vibrant FutureJournal of Biomaterials Applications, 1999
- Polyurethane heart valves: Fatigue failure, calcification, and polyurethane structureJournal of Biomedical Materials Research, 1997
- Calcification and fatigue failure in a polyurethane heart valveBiomaterials, 1995
- Chapter 16 Prosthetic Cardiac ValvesCardiovascular Pathology, 1993
- A synthetic three-leaflet valveJournal of Medical Engineering & Technology, 1992
- Comparative physical tests on segmented polyurethanes for cardiovascular applicationsClinical Materials, 1991
- The return of elastomer valvesThe Annals of Thoracic Surgery, 1989
- Hexsyn Trileaflet Valve: Application to Temporary Blood PumpsArtificial Organs, 1982
- The Design, Fabrication and Evaluation of a Trileaflet Prosthetic Heart ValveJournal of Biomechanical Engineering, 1980