Qualitative Detection of Hepatitis C Virus RNA: Comparison of Analytical Sensitivity, Clinical Performance, and Workflow of the Cobas Amplicor HCV Test Version 2.0 and the HCV RNA Transcription-Mediated Amplification Qualitative Assay
Open Access
- 1 August 2002
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 40 (8) , 2903-2907
- https://doi.org/10.1128/jcm.40.8.2903-2907.2002
Abstract
The qualitative Cobas Amplicor hepatitis C virus (HCV) version 2.0 assay (HCV PCR) and the Bayer Reference Testing Laboratory HCV RNA transcription-mediated amplification assay (HCV TMA) were compared for analytical sensitivity, clinical performance, and workflow. Limits of detection were determined by testing dilutions of the World Health Organization HCV standard in replicates of 15 at concentrations of from 1.0 to 70 IU/ml. The limit of detection of the HCV PCR assay was calculated to be 45 IU/ml on initial testing and 32 IU/ml after resolution of gray zone results. The calculated limit of detection for HCV TMA was 6 IU/ml. To compare clinical performance, 300 specimens, grouped as follows, were evaluated: 112 samples that were indeterminate in an anti-HCV enzyme immunoassay (EIA) and for which HCV RNA was not detected by HCV PCR; 79 samples that were EIA positive and for which HCV RNA was not detected by HCV PCR; and 105 samples that were both EIA and HCV PCR positive. For these groups, interassay concordance ranged from 96.2% to 100%. In addition, three HCV PCR gray zone specimens and one neonatal specimen were also evaluated. A 64-sample run (full run, 91 specimens) required 5 h for testing by HCV TMA, whereas almost 8 h were required to test a full run of 22 specimens by HCV PCR. HCV TMA demonstrated excellent concordance with HCV PCR when clinical samples were tested. However, HCV TMA was more sensitive than HCV PCR, required less time for test result completion, and had a greater throughput.Keywords
This publication has 26 references indexed in Scilit:
- Hepatitis C Virus InfectionNew England Journal of Medicine, 2001
- Relevance of Reactivity in Commercially Available Hepatitis C Virus Antibody AssaysJournal of Clinical Microbiology, 2001
- Performance characteristics of a transcription‐mediated nucleic acid amplification assay for qualitative detection of hepatitis C virus RNAJournal of Clinical Laboratory Analysis, 2001
- Detection of residual hepatitis C virus RNA by transcription-mediated amplification in patients with complete virologic response according to polymerase chain reaction-based assaysHepatology, 2000
- Evaluation of a new enzyme immunoassay for hepatitis C virus (HCV) core antigen with clinical sensitivity approximating that of genomic amplification of HCV RNAHepatology, 2000
- Establishment of the First International Standard for Nucleic Acid Amplification Technology (NAT) Assays for HCV RNAVox Sanguinis, 1999
- Establishment of the First International Standard for Nucleic Acid Amplification Technology (NAT) Assays for HCV RNAVox Sanguinis, 1999
- Safety and efficacy of hepatitis C virus antibody screening of blood donors with two sequential screening assaysTransfusion, 1996
- Comparison of two second‐generation anti‐hepatitis C virus ELISA on 21431 US blood donor samplesJournal of Viral Hepatitis, 1995
- Reliability of polymerase chain reaction for detection of hepatitis C virusThe Lancet, 1993