Spherical navigator echoes for full 3D rigid body motion measurement in MRI
Top Cited Papers
Open Access
- 20 December 2001
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 47 (1) , 32-41
- https://doi.org/10.1002/mrm.10012
Abstract
We developed a 3D spherical navigator (SNAV) echo technique that can measure rigid body motion in all six degrees of freedom simultaneously by sampling a spherical shell in k‐space. 3D rotations of an imaged object simply rotate the data on this shell and can be detected by registration of k‐space magnitude values. 3D translations add phase shifts to the data on the shell and can be detected with a weighted least‐squares fit to the phase differences at corresponding points. MRI pulse sequences were developed to study k‐space sampling strategies on such a shell. Data collected with a computer‐controlled motion phantom with known rotational and translational motions were used to evaluate the technique. The accuracy and precision of the technique depend on the sampling density. Roughly 2000 sample points were necessary for accurate detection to within the error limits of the motion phantom when using a prototype time‐intensive sampling method. This number of samples can be captured in an approximately 27‐ms double excitation SNAV pulse sequence with a 3D helical spiral trajectory. Preliminary results with the helical SNAV are encouraging and indicate that accurate motion measurement suitable for retrospective or prospective correction should be feasible with SNAV echoes. Magn Reson Med 47:32–41, 2002.Keywords
This publication has 23 references indexed in Scilit:
- A prospective approach to correct for inter‐image head rotation in FMRIMagnetic Resonance in Medicine, 1998
- Movement‐Related effects in fMRI time‐seriesMagnetic Resonance in Medicine, 1996
- Orbital navigator echoes for motion measurements in magnetic resonance imagingMagnetic Resonance in Medicine, 1995
- Motion Artifacts in fMRI: Comparison of 2DFT with PR and Spiral Scan MethodsMagnetic Resonance in Medicine, 1995
- Spatial‐Frequency‐Tuned Markers and Adaptive Correction for Rotational MotionMagnetic Resonance in Medicine, 1995
- Artifacts due to stimulus correlated motion in functional imaging of the brainMagnetic Resonance in Medicine, 1994
- Projection Reconstruction Techniques for Reduction of Motion Effects in MRIMagnetic Resonance in Medicine, 1992
- Altered phase‐encoding order for reduced sensitivity to motion in three‐dimensional MR imagingJournal of Magnetic Resonance Imaging, 1992
- FLASH imaging. Rapid NMR imaging using low flip-angle pulsesJournal of Magnetic Resonance (1969), 1986