Computed Tomography of Posterior Uveal Melanomas
- 1 November 1987
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 105 (11) , 1512-1516
- https://doi.org/10.1001/archopht.1987.01060110058031
Abstract
• Computed tomographic (CT) scans were obtained from 48 patients with posterior uveal melanoma. The CT measurements of maximal and minimal basal diameters and thickness of each tumor were compared with the assessments of these tumor dimensions obtained by ophthalmoscopic estimation (basal diameters only) and standardized A-scan ultrasonography (thickness only) and with the gross pathologic measurements of these tumors. The correlation between measurements of tumor thickness by CT scanning, standardized A-scan ultrasonography, and gross pathologic analysis was substantially better than that between the CT, ophthalmoscopic, and gross pathologic measurements of tumor basal diameters. Computed tomographic scanning appears to be a good method for determining the in vivo size of choroidal and ciliary body melanomas.This publication has 4 references indexed in Scilit:
- COMPUTERIZED TOMOGRAPHY OF MALIGNANT MELANOMAS OF THE CHOROIDActa Ophthalmologica, 1983
- CT of the orbit: Current status with high resolution computed tomographyNeuroradiology, 1983
- The use of computed tomography and ultrasonography in the evaluation of orbital massesSurvey of Ophthalmology, 1982
- Diagnostic Modalities in Choroidal MelanomaAmerican Journal of Ophthalmology, 1980