Evaluation of a 16-MDCT Scanner in an Emergency Department: Initial Clinical Experience and Workflow Analysis
- 1 July 2005
- journal article
- research article
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 185 (1) , 232-238
- https://doi.org/10.2214/ajr.185.1.01850232
Abstract
OBJECTIVE. MDCT is especially suited for emergency purposes because it allows rapid high-resolution scans of large areas, fast high-quality reformatting in every orientation, and 3D illustration of the data set. In a prospective study, we evaluated the reliability and workflow of a dedicated emergency department 16-MDCT scanner in the management of patients presenting to the emergency department. SUBJECTS AND METHODS. The use of a 16-MDCT scanner for 503 patients in the emergency department of a university clinic was evaluated. For reasons of workflow analysis, seven precise time intervals were recorded during the emergency examinations. A new setting for repositioning multiple-trauma patients after imaging of the head and neck from the head-first position to the feet-first position was introduced. RESULTS. Six (1.2%) of the 503 patients were excluded because of technical malfunction or patient noncompliance. Image quality in the remaining 497 cases, including CT angiography and CT of multiple-trauma patients, was outstanding. Positioning of the patients took from 3 to 13 min depending on the body region examined, representing 33-67% of the mean room time, which ranged from 8 to 21 min. In multiple-trauma patients, the initial positioning took a mean of 6 min and repositioning took 8 min, representing 19% and 26% of total room time, respectively. CONCLUSION. The use of a dedicated 16-MDCT scanner in the emergency department resulted in short examination times even for examinations of multiple body regions under emergency conditions. The introduced setting—repositioning of multiple-trauma patients—allowed high image quality to be maintained. The trade-off in multiple-trauma patients was prolonged room time because of patient repositioning.Keywords
This publication has 16 references indexed in Scilit:
- High-Resolution CT Using MDCT: Comparison of Degree of Motion Artifact Between Volumetric and Axial MethodsAmerican Journal of Roentgenology, 2004
- Clinical experience with multihance in CNS imagingEuropean Radiology, 2003
- Radiological emergency room management with emphasis on multidetector-row CTEuropean Journal of Radiology, 2003
- Three-dimensional volume rendering of multidetector-row CT data: applicable for emergency radiologyEuropean Journal of Radiology, 2003
- General principles of MDCTEuropean Journal of Radiology, 2003
- Dedicated CT Scanner in an Emergency Department: Quantification of Factors That Contribute to Lack of UseAmerican Journal of Roentgenology, 2002
- The AAPM/RSNA Physics Tutorial for ResidentsRadioGraphics, 2002
- Helical CT in Emergency RadiologyRadiology, 1999
- Subsecond multi-slice computed tomography: basics and applicationsEuropean Journal of Radiology, 1999
- Radiologisches Notfallmanagement polytraumatisierter PatientenDer Radiologe, 1998