Quantification of regional myocardial perfusion with generator-produced 62Cu-PTSM and positron emission tomography.
- 1 January 1993
- journal article
- abstracts
- Published by Wolters Kluwer Health in Circulation
- Vol. 87 (1) , 173-183
- https://doi.org/10.1161/01.cir.87.1.173
Abstract
BACKGROUND Noninvasive assessment of regional myocardial perfusion at rest and after stress is important for the objective evaluation of the effects of coronary artery disease and its response to therapy. Centers that do not have cyclotrons rely on generator-produced radioisotopes for assessment of regional myocardial perfusion with positron emission tomography (PET). The aim of the present study was to develop and implement an approach to quantify regional myocardial perfusion using copper(II) pyruvaldehyde bis-(N4-thiosemicarbazone) (PTSM) labeled with the generator-produced, positron-emitting radionuclide 62Cu (t1/2 = 9.7 minutes). METHODS AND RESULTS Regional perfusion was estimated from dynamic PET scans after intravenous administration of 62Cu-PTSM in 21 studies in 13 intact dogs evaluated over a wide range of myocardial flow values. In 15 interventions in nine dogs, regional perfusion was also estimated with H2(15)O. Regional perfusion with 62Cu-PTSM was estimated from dynamic blood and tissue time-activity curves, along with the model parameter k1 (forward rate of transport) and the PET parameter FBM (fraction of blood pool activity observed in tissue), using a two-compartment kinetic model. Arterial blood activity was corrected for red blood cell-associated 62Cu. In 44 comparisons, estimates of regional perfusion with 62Cu-PTSM correlated well with estimates obtained with concomitantly administered radiolabeled microspheres (y = 0.90x +/- 0.15, r = 0.95, p < 0.05) over a flow range from 0.23 to 6.14 ml/g per minute. In five healthy human volunteers evaluated at rest with H2(15)O and 62Cu-PTSM, regional perfusion estimated with 62Cu-PTSM was not significantly different from that obtained with H2(15)O (1.05 +/- 0.36 versus 0.96 +/- 0.28 ml/g per minute). 62Cu-PTSM provided high-quality images of the heart. CONCLUSIONS The results of this study demonstrate that quantification of regional myocardial perfusion is feasible using generator-produced 62Cu-PTSM. Since 62Cu-PTSM can be used to estimate perfusion in the brain, kidney, and tumors as well as in the heart, it is an attractive tracer for centers that rely on generator-produced tracers for the evaluation of perfusion with PET.Keywords
This publication has 12 references indexed in Scilit:
- A remote system for the synthesis of copper-62 labeled Cu(PTSM)International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, 1991
- Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery diseaseThe American Journal of Cardiology, 1991
- Noninvasive quantification of regional blood flow in the human heart using N-13 ammonia and dynamic positron emission tomographic imagingJournal of the American College of Cardiology, 1990
- Quantitation of Myocardial Blood Flow with H215O and Positron Emission TomographyJournal of Computer Assisted Tomography, 1989
- Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomographyJournal of the American College of Cardiology, 1989
- Measurement of absolute myocardial blood flow with H215O and dynamic positron-emission tomography. Strategy for quantification in relation to the partial-volume effect.Circulation, 1988
- Rubidium-82 Myocardial Uptake and Extraction After Transient IschemiaJournal of Computer Assisted Tomography, 1987
- Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VIII. Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced Rubidium-82Journal of the American College of Cardiology, 1986
- Temporal dependence of beneficial effects of coronary thrombolysis characterized by positron tomographyThe American Journal of Medicine, 1982
- Blood flow measurements with radionuclide-labeled particlesProgress in Cardiovascular Diseases, 1977