Comparison of Liquid Chromatography with Fluorescence Detection and Gas Chromatography/Mass Spectrometry for the Determination of Polycyclic Aromatic Hydrocarbons in Environmental Samples
- 1 February 1990
- journal article
- research article
- Published by Taylor & Francis in Polycyclic Aromatic Compounds
- Vol. 1 (1-2) , 81-98
- https://doi.org/10.1080/10406639008034751
Abstract
Liquid chromatography (LC) with fluorescence detection and gas chromatography/mass spectrometry (GC/MS) have been compared for the determination of polycyclic aromatic hydrocarbons (PAHs) in a variety of environmental samples. Three sets of data are presented in this paper in which LC/fluorescence and GC/MS were used for the analysis of the same samples. These three data sets include the comparison of results from: (1) certification measurements for three natural matrix Standard Reference Materials (SRM's), (2) an international round robin for the determination of PAHs in air and diesel particulate samples, and (3) the analysis of four marine sediment reference materials. The results from these studies indicate that the two techniques generally provide comparable results for the measurement of PAHs in environmental samples (in the range of 0.1 to 300 ng/g), with differences in the two techniques between 5–20%. However, at low levels, anthracene and perylene are best measured using LC/fluorescence because of their selective and sensitive fluorescence detection characteristics. In contrast, GC/MS provides more accurate results for the determination of benzo[ghi]perylene because of its low fluorescence sensitivity.Keywords
This publication has 11 references indexed in Scilit:
- Determination of polycyclic aromatic hydrocarbons in a coal tar standard reference materialAnalytical Chemistry, 1988
- Standard reference materials for the determination of polycyclic aromatic hydrocarbonsAnalytical and Bioanalytical Chemistry, 1988
- Determination of polycyclic aromatic hydrocarbons and alkylated-polycyclic aromatic hydrocarbons in particulate extracts using negative ion chemical ionization mass spectrometryJournal of Mass Spectrometry, 1987
- Characterization of the polycyclic aromatic hydrocarbons from two standard reference material air particulate samplesAnalytical Chemistry, 1986
- Factors affecting the reversed‐phase liquid chromatographic separation of polycyclic aromatic hydrocarbon isomersJournal of High Resolution Chromatography, 1985
- The Application of Perdeuterated Polycyclic Aromatic Hydrocarbons (PAH) as Internal Standards for the Liquid Chromatographic Determination of PAH in a Petroleum Crude Oil and Other Complex MixturesJournal of Liquid Chromatography, 1985
- Selectivity of negative ion chemical ionization mass spectrometry for benzo[a]pyreneAnalytical Chemistry, 1984
- Liquid chromatographic determination of polycyclic aromatic hydrocarbons in air particulate extractsAnalytical Chemistry, 1984
- Determination of individual organic compounds in shale oilAnalytical Chemistry, 1980
- Chemically-bonded aminosilane stationary phase for the high-performance liquid chromatographic separation of polynuclear aromatic compoundsAnalytical Chemistry, 1977