Can peripheral venous blood gases replace arterial blood gases in emergency department patients?
- 1 January 2002
- journal article
- Published by Springer Nature in CJEM
- Vol. 4 (01) , 7-15
- https://doi.org/10.1017/s1481803500006011
Abstract
Objective:To determine if peripheral venous blood gas values for pH, partial pressure of carbon dioxide (PCO2) and the resultant calculated bicarbonate (HCO3) predict arterial values accurately enough to replace them in a clinical setting.Methods:This prospective observational study was performed in a university tertiary care emergency department from June to December 1998. Patients requiring arterial blood gas analysis were enrolled and underwent simultaneous venous blood gas sampling. The following data were prospectively recorded: age, sex, presenting complaint, vital signs, oxygen saturation, sample times, number of attempts and indication for testing. Correlation coefficients and mean differences with 95% confidence intervals (CIs) were calculated for pH, PCO2 and HCO3. A survey of 45 academic emergency physicians was performed to determine the minimal clinically important difference for each variable.Results:The 218 subjects ranged in age from 15 to 90 (mean 60.4) years. The 2 blood samples were drawn within 10 minutes of each other for 205 (96%) of the 214 patients for whom data on timing were available. Pearson’s product–moment correlation coefficients between arterial and venous values were as follows: pH, 0.913; PCO2, 0.921; and HCO3, 0.953. The mean differences (and 95% CIs) between arterial and venous samples were as follows: pH, 0.036 (0.030–0.042); PCO2, 6.0 (5.0–7.0) mm Hg; and HCO3, 1.5 (1.3–1.7) mEq/L. The mean differences (± 2 standard deviations) were greater than the minimum clinically important differences identified in the survey.Conclusions:Arterial and venous blood gas samples were strongly correlated, and there were only small differences between them. A survey of emergency physicians suggested that the differences are too large to allow for interchangeability of results; however, venous values may be valid if used in conjunction with a correction factor or for trending purposes.Keywords
This publication has 11 references indexed in Scilit:
- Comparison of Arterial and Venous Blood Gas Values in the Initial Emergency Department Evaluation of Patients With Diabetic KetoacidosisAnnals of Emergency Medicine, 1998
- Correlation versus agreement: Methods of measurement in medicineAnnals of Emergency Medicine, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- The usefulness of peripheral venous blood in estimating acid-base status in acutely III patientsAnnals of Emergency Medicine, 1985
- Measurement in Medicine: The Analysis of Method Comparison StudiesJournal of the Royal Statistical Society: Series D (The Statistician), 1983
- Clinical Sequelae from Arterial Needle Puncture, Cannulation, and IncisionCirculation, 1967
- The Accuracy of Venous and Capillary Blood for the Prediction of Arterial pH, Pco2, and Po2MeasurementsAmerican Journal of Clinical Pathology, 1966
- Normal Values for Adult Human Venous Plasma pH and CO2 ContentAmerican Journal of Clinical Pathology, 1959
- Comparisons of pH in Human Arterial, Venous, and Capillary BloodAmerican Journal of Clinical Pathology, 1959
- USE OF VENOUS BLOOD FOR pH AND CARBON-DIOXIDE STUDIES: ESPECIALLY IN RESPIRATORY FAILURE AND DURING ANÆSTHESIAThe Lancet, 1959