Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluation
- 20 February 2002
- journal article
- Published by Wiley in Medical Physics
- Vol. 29 (3) , 351-355
- https://doi.org/10.1118/1.1449493
Abstract
X‐ray film has been used for the dosimetry of intensity modulated radiation therapy (IMRT). However, the over‐response of the film to low‐energy photons is a significant problem in photon beam dosimetry, especially in regions outside penumbra. In IMRT, the radiation field consists of multiple small fields and their outside‐penumbra regions; thus, the film dosimetry, for it involves the source of over‐response in its radiation field. In this study we aim to verify and possibly improve film dosimetry for IMRT. Two types of modulated beams were constructed by combining five to seven different static radiation fields using 6 MV x rays. For verifying film dosimetry, x‐ray films and an ion chamber were used to measure dose profiles at various depths in a phantom. The film setups include both parallel and perpendicular arrangements against the beam incident direction. In addition, to reduce an over‐response, we placed 0.01 in. (0.25 mm) thick lead filters on both sides of the film. Compared with ion‐chamber measurement, measured dose profiles showed the film over‐response at outside‐penumbra and low‐dose regions. The error increased with depths and approached 15% as a maximum for the field size of at 10 cm depth. The use of filters reduced the error down to 3%. In this study we demonstrated that film dosimetry for IMRT involves sources of error due to its over‐response to low‐energy photons, with the error most transparent in the low‐dose region. The use of filters could enhance the accuracy in film dosimetry for IMRT. In this regard, the use of an optimal filter condition is recommended.Keywords
This publication has 7 references indexed in Scilit:
- Quantitative dosimetric verification of an IMRT planning and delivery systemRadiotherapy and Oncology, 1998
- Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapyMedical Physics, 1998
- A filtration method for improving film dosimetry in photon radiation therapyMedical Physics, 1997
- Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: A strategy for large-scale implementation for the treatment of carcinoma of the prostateInternational Journal of Radiation Oncology*Biology*Physics, 1997
- Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck regionInternational Journal of Radiation Oncology*Biology*Physics, 1997
- A new approach to film dosimetry for high energy photon beams: Lateral scatter filteringMedical Physics, 1997
- Dosimetric verification of intensity‐modulated fieldsMedical Physics, 1996