Rapid online quantification of left ventricular volume from real-time three-dimensional echocardiographic data
Top Cited Papers
Open Access
- 30 November 2005
- journal article
- research article
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 27 (4) , 460-468
- https://doi.org/10.1093/eurheartj/ehi666
Abstract
Aims Determination of left ventricular (LV) volumes and ejection fraction (EF) from two-dimensional echocardiographic (2DE) images is subjective, time-consuming, and relatively inaccurate because of foreshortened views and the use of geometric assumptions. Our aims were (1) to validate a new method for rapid, online measurement of LV volumes from real-time three-dimensional echocardiographic (RT3DE) data using cardiac magnetic resonance (CMR) as the reference and (2) to compare its accuracy and reproducibility with standard 2DE measurements. Methods and results CMR, 2DE, and RT3DE datasets were obtained in 50 patients. End-systolic and end-diastolic volumes (ESV and EDV) were calculated from the 2DE images using biplane method of disks. ES and ED RT3DE datasets were analysed using prototype software designed to automatically detect the endocardial surface using a deformable shell model and calculate ESV and EDV from voxel counts. 2DE and RT3DE-derived volumes were compared with CMR (linear regression, Bland–Altman analysis). In most patients, analysis of RT3DE data required r: 0.96, 0.97, and 0.93 for EDV, ESV, and EF, respectively) with small biases (−14 mL, −6.5 mL, −1%) and narrow limits of agreement (SD: 17 mL, 16 mL, 6.4%). 2DE measurements correlated less well with CMR (r: 0.89, 0.92, 0.86) with greater biases (−23 mL, −15 mL, 1%) and wider limits of agreement (SD: 29 mL, 24 mL, 9.5%). RT3DE resulted in lower intra-observer (EDV: 7.9 vs. 23%; ESV: 7.6 vs. 26%) and inter-observer variability (EDV: 11 vs. 26%; ESV: 13 vs. 31%). Conclusion Semi-automated detection of the LV endocardial surface from RT3DE data is suitable for clinical use because it allows rapid, accurate, and reproducible measurements of LV volumes, superior to conventional 2DE methods.Keywords
This publication has 21 references indexed in Scilit:
- Volumetric Quantification of Global and Regional Left Ventricular Function From Real-Time Three-Dimensional Echocardiographic ImagesCirculation, 2005
- Improved Semiautomated Quantification of Left Ventricular Volumes and Ejection Fraction Using 3-Dimensional Echocardiography with a Full Matrix-array Transducer: Comparison with Magnetic Resonance ImagingJournal of the American Society of Echocardiography, 2005
- Fast Measurement of Left Ventricular Mass With Real-Time Three-Dimensional EchocardiographyCirculation, 2004
- High-resolution transthoracic real-time three-dimensional echocardiographyJournal of the American College of Cardiology, 2004
- Accuracy of three-dimensional echocardiography with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fractionAmerican Heart Journal, 2000
- Importance of imaging method over imaging modality in noninvasive determination of left ventricular volumes and ejection fractionJournal of the American College of Cardiology, 2000
- Assessment of Cardiac Function by Three-dimensional Echocardiography Compared With Conventional Noninvasive MethodsCirculation, 1995
- Comparison of two- and three-dimensional echocardiography with cineventriculography for measurement of left ventricular volume in patientsJournal of the American College of Cardiology, 1994
- Left ventricular volume and endocardial surface area by three-dimensional echocardiography: Comparison with two-dimensional echocardiography and nuclear magnetic resonance imaging in normal subjectsJournal of the American College of Cardiology, 1993
- Left ventricular end-systolic volume as the major determinant of survival after recovery from myocardial infarction.Circulation, 1987