Comparison of jugular venous oxygen saturation and brain tissue PO2 as monitors of cerebral ischemia after head injury
- 1 November 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 27 (11) , 2337-2345
- https://doi.org/10.1097/00003246-199911000-00003
Abstract
To compare the characteristics of jugular venous oxygen saturation (SjvO2) and brain tissue PO2 (PbtO2) as monitors for cerebral ischemia after severe head injury. SjvO2 has been useful as a monitor for cerebral ischemia, but it is limited by its inability to identify regional cerebral ischemia. PbtO2 may be superior to SjvO2 for this purpose, because oxygenation in localized areas of the brain can be monitored. SjvO2 and PbtO2 were successfully monitored in 58 patients with severe head injury. The changes in SjvO2 and PbtO2 were compared during ischemic episodes. Neurosurgical intensive care unit of a level I trauma center. During the monitoring period, which averaged 90 hrs/patient, there were 54 episodes during which SjvO2 decreased to <50% and/or PbtO2 decreased to <8 torr. Two of these episodes were caused by an infarction in the area of the PO2 probe, leaving 52 episodes of global hypoxia/ischemia that were identified by one of the two monitors. The sensitivities of the two monitors for detecting ischemia, using the thresholds of 50% and 8 torr for SjvO2 and PbtO2, respectively, were similar. The SjvO2 catheter detected 69.7% of the episodes and the PbtO2 catheter detected 63.5% of the episodes. In most of the remaining episodes, both probes reflected a decrease in oxygenation, but not to levels below the defined thresholds. The major differences in the two measures of oxygenation included the following: a) SjvO2 more consistently reflected a reduction in oxygenation during hyperventilation; b) PbtO2 was affected more by changes in arterial PO2; and c) during severe global ischemia, PbtO2 decreased to 0 and remained at 0, whereas SjvO2 initially decreased but then increased again as cerebral blood flow ceased, and the only blood in the jugular bulb was of extracerebral origin. The two monitors provide complimentary information, and neither monitor alone identifies all episodes of ischemia. The best strategy for using these monitors is to take advantage of the unique features of each monitor. SjvO2 should be used as a monitor of global oxygenation; but PbtO2 should be used as a monitor of local oxygenation, ideally with the catheter placed in an area of the brain that is vulnerable to ischemia but that may be salvageable with appropriate treatment.Keywords
This publication has 34 references indexed in Scilit:
- Evaluation of a regional oxygen saturation catheter for monitoring SJVO2 in head injured patientsJournal of Clinical Monitoring and Computing, 1996
- Brain tissue pO2 in relation to cerebral perfusion pressure, TCD findings and TCD-CO2-reactivity after severe head injuryActa Neurochirurgica, 1996
- Jugular venous desaturation and outcome after head injury.Journal of Neurology, Neurosurgery & Psychiatry, 1994
- Ultra-early evaluation of regional cerebral blood flow in severely head-injured patients using xenon-enhanced computerized tomographyJournal of Neurosurgery, 1992
- Cerebral blood flow, arteriovenous oxygen difference, and outcome in head injured patients.Journal of Neurology, Neurosurgery & Psychiatry, 1992
- Cerebral arteriovenous oxygen difference as an estimate of cerebral blood flow in comatose patientsJournal of Neurosurgery, 1989
- The use of intermittent and continuous recordings of jugular venous bulb oxygen saturation in the unconscious patientScandinavian Journal of Clinical and Laboratory Investigation, 1987
- HYPOXIC INSULTS IN ACUTE BRAIN INJURYCritical Care Medicine, 1985
- Cerebral circulation after head injuryJournal of Neurosurgery, 1983
- Cerebral circulation after head injuryJournal of Neurosurgery, 1981