Comparison of Cerebral Blood Volume Measured by Near Infrared Spectroscopy and Contrast Enhanced Magnetic Resonance Imaging
- 1 January 1999
- book chapter
- Published by Springer Nature
- Vol. 471, 767-773
- https://doi.org/10.1007/978-1-4615-4717-4_88
Abstract
Cerebral blood volume (CBV) can be quantified by both near infrared spectroscopy (NIRS) and magnetic resonance imaging (MRI). The aim is to compare CBV results obtained by NIRS and MRI in adult patients. 10 adult patients, 6 females and 4 males, age median 24 (range 21 to 76) years, were included in this study. All needed a MRI investigation with contrast medium for clinical reasons. The NIRS instrument, the Cerebral RedOx Monitor 2020 from Critikon, quantifies cerebral haemoglobin concentration using a sensor with two receiving channels at different distances. Geometrical detector arrangements of this type enable a ratio measurement to be achieved, which reduces the contribution of the skull and skin, thus allowing quantification. Cerebral haemoglobin concentration can be converted in CBV, as the haemoglobin concentration in the blood is known. CBV can be quantified by MRI using an indicator dilution method. The method requires an injection of a paramagnetic contrast agent. The input function can be measured at the throat and thus perfusion images can be quantified. CBV was measured by NIRS just before the patient entered the magnet and after he had left it. The sensor for the NIRS measurement was applied to the patients front three times for 1 minute to each side, avoiding the sinuses. CBV was determined by contrast enhanced MRI between the NIRS measurements. The mean CBV (NIRS) was 8.6 (SD 1.3) ml/100g and CBV (MRI) was 7.1 (SD 2.5). The correlation between CBV (NIRS) and CBV (MRI) was Pearson’s correlation coefficient -0.297 (p = 0.204) respectively Spearman’s rho (nonparametric) -0.266 (p = 0.257). The CBV values obtained by NIRS and MRI, even though they are in the same range, do not correlate.Keywords
This publication has 9 references indexed in Scilit:
- An investigation of light transport through scattering bodies with non-scattering regionsPhysics in Medicine & Biology, 1996
- Use of near infrared spectroscopy to estimate cerebral blood flow in conscious and anaesthetized adult subjectsBritish Journal of Anaesthesia, 1996
- Theoretical and experimental investigation of the effect of sulci on light propagation in brain tissuePublished by SPIE-Intl Soc Optical Eng ,1995
- Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging.Radiology, 1994
- Comparison between Near Infrared Spectroscopy and 133Xenon Clearance for Estimation of Cerebral Blood Flow in Critically Ill Preterm InfantsPediatric Research, 1993
- Estimating Cerebral Blood Flow in Newborn Infants: Comparison of Near Infrared Spectroscopy and 133Xe ClearancePediatric Research, 1991
- Quantitation of cerebral blood volume in human infants by near-infrared spectroscopyJournal of Applied Physiology, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986