Sensitivity studies of beam directionality, beam size, and neutron spectrum for a fission converter‐based epithermal neutron beam for boron neutron capture therapy
- 7 September 1999
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 26 (9) , 1979-1988
- https://doi.org/10.1118/1.598784
Abstract
Sensitivity studies of epithermal neutron beam performance in boron neutron capture therapy are presented for realistic neutron beams with varying filter/moderator and collimator/delimiter designs to examine the relative importance of neutron beam spectrum, directionality, and size. Figures of merit for in-air and in-phantom beam performance are calculated via the Monte Carlo technique for different well-optimized designs of a fission converter-based epithermal neutron beam with head phantoms as the irradiation target. It is shown that increasing a measure of beam directionality, does not always lead to corresponding monotonic improvements in beam performance. Due to the relatively low significance, for most configurations, of its effect on in-phantom performance and the large intensity losses required to produce beams with very high beam directionality should not be considered an important figure of merit in epithermal neutron beam design except in terms of its consequences on patient positioning and collateral dose. Hardening the epithermal beam spectrum, while maintaining the specific fast neutron dose well below the inherent hydrogen capture dose, improves beam penetration and advantage depth and, as a desirable by-product, significantly increases beam intensity. Beam figures of merit are shown to be strongly dependent on beam size relative to target size. Beam designs with specific fast neutron doses of
Keywords
This publication has 18 references indexed in Scilit:
- The Radiation Biology of Boron Neutron Capture TherapyRadiation Research, 1999
- Boron Neutron-Capture Therapy (BNCT) for Glioblastoma Multiforme (GBM) Using the Epithermal Neutron Beam at the Brookhaven National LaboratoryInternational Journal of Radiation Oncology*Biology*Physics, 1998
- An improved neutron collimator for brain tumor irradiations in clinical boron neutron capture therapyMedical Physics, 1996
- Monte Carlo-based treatment planning for boron neutron capture therapy using custom designed models automatically generated from CT dataInternational Journal of Radiation Oncology*Biology*Physics, 1996
- Recent Study of Boron Neutron Capture Therapy for Malignant Brain Tumor in JapanPublished by Springer Nature ,1996
- Head phantoms for neutron capture therapyMedical Physics, 1995
- Generating Epithermal Neutron Beams for Neutron Capture Therapy in Small ReactorsPublished by Springer Nature ,1993
- TREATMENT OF MALIGNANT MELANOMA BY SINGLE THERMAL NEUTRON CAPTURE THERAPY WITH MELANOMA-SEEKING 10B-COMPOUNDThe Lancet, 1989
- Boron neutron capture therapy for the treatment of cerebral gliomas. I: Theoretical evaluation of the efficacy of various neutron beamsMedical Physics, 1975