Determination of 23 Polycyclic Aromatic Hydrocarbons in Atmospheric Particulate Matter of the Paris Area and Photolysis by Sunlight
- 1 January 1985
- journal article
- research article
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 19 (2) , 111-131
- https://doi.org/10.1080/03067318508077022
Abstract
Twenty-three polycyclic aromatic hydrocarbons (PAH) were determined in atmospheric particulate matter in 4 places of the Paris area at several times of the year. Fractionation was performed by reversed-phase high-pressure liquid chromatography. Determination was done by recording emission or excitation fluorescence spectra via a stopped-flow technique. Triphenylene was also extemporaneously determined by its phosphorescence spectrum at low temperature. Among the PAH determined dibenz(e, ghi)perylene has not been detected before in atmospheric particulate matter. The 10 more abundant PAH ranged from 0.1 to 40ng/m3 of filtered air. Concentrations in August are from 14 to 250 times less than in January depending on the PAH. The reasons for this difference of behaviour among the PAH were investigated with regard to their photochemical and non-photochemical reactivity.Keywords
This publication has 13 references indexed in Scilit:
- Comparison of the Profiles of Polycyclic Aromatic Hydrocarbons in Different Areas of a City by Glass-Capillary-Gas-Chromatography in the Nanogram-RangeInternational Journal of Environmental Analytical Chemistry, 1981
- Correlations between lead and coronene concentrations at urban, suburban, and industrial sites in New JerseyEnvironmental Science & Technology, 1981
- Reactivity of polycyclic aromatic hydrocarbons adsorbed on soot particlesAtmospheric Environment (1967), 1981
- Evaluation of bonded phases for the high-performance liquid chromatographic determination of polycyclic aromatic hydrocarbons in effluent watersJournal of Chromatography A, 1981
- Method for measurement of polycyclic aromatic hydrocarbons in particulate matter in ambient airTalanta, 1980
- Losses of benzo(a)pyrene under the conditions of high-volume samplingAtmospheric Environment (1967), 1980
- Testing a high volume air sampler for quantitative collection of polycyclic aromatic hydrocarbonsAtmospheric Environment (1967), 1980
- Fluorescence detection in high performance liquid chromatographic determination of polycyclic aromatic hydrocarbonsAnalytical Chemistry, 1978
- A fluorescence detector for high-pressure liquid chromatographyJournal of Chromatography A, 1977
- Residence time of particles in urban airAtmospheric Environment (1967), 1971