Abstract
Due to practical limitations in data acquisition, 3-D computed tomography systems must attempt to provide rapid reconstructions of acceptable quality from a limited number of views. The use of convolution backprojection (CBP) for image reconstruction from an inadequate number of projections, results in view aliasing artifacts. In this paper we investigate different post-processing methods of alleviating the effects of view aliasing artifacts. Two distinct methods and their variants are considered. The first, termed the intermediate view reprojection (IVR) method, involves estimating a set of intermediate views by reprojection, followed by a reconstruction using the augmented set of views. The second, termed the error-correction (EC) method, incorporates a correction on the initial reconstruction based on the projection-domain error. Suitable modifications and variants of the above methods are indicated. Of the methods discussed, the IVR method is simple, tends to reduce the effects of artifacts with less susceptibility to secondary effects, and is applicable to region-of-interest reconstructions.Keywords
This publication has 21 references indexed in Scilit:
- Algebraic Reconstruction Techniques (ART) for three-dimensional electron microscopy and X-ray photographyPublished by Elsevier ,2004
- Three-dimensional vascular reconstruction with a clinical X-ray angiography systemAcademic Radiology, 1997
- Three‐dimensional computed tomographic reconstruction using a C‐arm mounted XRII: Correction of image intensifier distortionMedical Physics, 1997
- Compensation for attenuation, scatter, and detector response in SPECT reconstruction via iterative FBP methodsMedical Physics, 1993
- Algorithms for limited-view computed tomography: an annotated bibliography and a challengeApplied Optics, 1985
- Iterative convolution backprojection algorithms for image reconstruction from limited dataJournal of the Optical Society of America, 1983
- Iterative Reconstruction-Reprojection: An Algorithm for Limited Data Cardiac-Computed TomographyIEEE Transactions on Biomedical Engineering, 1982
- An algorithm for the reduction of metal clip artifacts in CT reconstructionsMedical Physics, 1981
- Tomographical imaging with limited-angle inputJournal of the Optical Society of America, 1981
- Tomographic image reconstruction from limited projections using iterative revisions in image and transform spacesApplied Optics, 1981