Cerebral Protection During Carotid Artery Stenting
- 1 February 2002
- journal article
- other
- Published by Wolters Kluwer Health in Stroke
- Vol. 33 (2) , 456-461
- https://doi.org/10.1161/hs0202.102337
Abstract
Background and Purpose — Histopathologic analysis was performed to better understand quantity, particle size, and composition of embolized debris collected in protection filters during carotid artery stent implantation. Methods — Elective carotid stent implantation with the use of a distal filter protection was attempted in 38 consecutive lesions (36 patients) of the internal carotid artery presenting >70% diameter stenosis (mean, 82.1±11.1%). Mean age of the patients was 70.7±7.7 years; 75% were men, and 50% of patients had previous neurological symptoms. Results — In 37 lesions (97.4%) it was possible to position the filter device, and in all lesions a stent was successfully implanted. The only complication occurring in the hospital and during the 30-day follow-up was 1 death due to acute myocardial infarction. Neurological sequelae did not occur. Histomorphometric analysis was performed on the filters. Presence of debris was detected in 83.7% of filters. The mean surface area of the polyurethane membrane filter covered with material was 53.2±19.8%. Particle size ranged from 1.08 to 5043.5 μm (mean, 289.5±512 μm) in the major axis and 0.7 to 1175.3 μm (mean, 119.7±186.7 μm) in the minor axis. Collected debris consisted predominantly of thrombotic material, foam cells, and cholesterol clefts. Conclusions — By the use of distal protection filters during carotid artery stenting, it was possible to collect particulate debris potentially leading to distal vessel occlusion in a high percentage of cases. Qualitative analysis of embolized material showed debris dislocated during the percutaneous intervention from atheromatous plaques.Keywords
This publication has 12 references indexed in Scilit:
- Initial evaluation of carotid angioplasty and stenting with three different cerebral protection devicesJournal of Vascular Surgery, 2000
- Carotid Artery Stent Placement for Atherosclerotic Disease: Rationale, Technique, and Current StatusRadiology, 2000
- Efficacy of a filter device in the prevention of embolic events during carotid angioplasty and stenting: An ex vivo analysisJournal of Vascular Surgery, 1999
- Carotid Stenting With Cerebral Protection: First Clinical Experience Using the PercuSurge GuardWire SystemJournal of Endovascular Surgery, 1999
- Stent Placement versus Percutaneous Transluminal Angioplasty of Human Carotid Arteries in Cadavers in Situ: Distal Embolization and Findings at Intravascular US, MR Imaging, and Histopathologic AnalysisRadiology, 1999
- Microemboli detected by transcranial Doppler monitoring in patients during carotid angioplasty versus carotid endarterectomyCardiovascular Surgery, 1998
- Carotid artery stenosis: treatment with protected balloon angioplasty and stent placement.Radiology, 1996
- The significance of microemboli detection by means of transcranial Doppler ultrasonography monitoring in carotid endarterectomyJournal of Vascular Surgery, 1995
- Clinical relevance of intraoperative embolization detected by transcranial Doppler ultrasonography during carotid endarterectomy: A prospective study of 100 patientsBritish Journal of Surgery, 1994
- Beneficial Effect of Carotid Endarterectomy in Symptomatic Patients with High-Grade Carotid StenosisNew England Journal of Medicine, 1991