Acute Efficacy and Chronic Follow‐Up of Patients with Non‐Thoracotomy Third Generation Implantahle Defibrillators
- 1 March 1994
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 17 (3) , 499-505
- https://doi.org/10.1111/j.1540-8159.1994.tb01417.x
Abstract
Non-thoracotomy implantation of implantable cardioverter defibrillators (ICDs) has simplified the process of device insertion, promising to decrease associated procedural complications while providing sudden death protection at least equal to epicardial systems. This study presents the acute and chronic results of 110 patients who underwent attempted non-thoracotomy ICD implantation with the Medtronic Transvene lead system and PCD model 7217 or 7219. Of the 110 patients attempted, 100 (91%) had the system successfully implanted without the need for an epicardial patch. One patient died 1 week postoperatively of septic shock related to the implantation (0.9% perioperative mortality). During follow-up of 16 +/- 11 months, 45% of the patients had an event detected as ventricular tachycardia; 26% of these detections were felt clinically to be due to supraventricular rhythms. Of the remainder, 87% were successfully treated with the first VT therapy, and 98% were terminated by the final therapy; 66% of the patients had at least one episode of ventricular fibrillation, of which 5% were felt to be inappropriate detections; 85% of the appropriate episodes were successfully treated with the first VF therapy, and all were converted by the final therapy. Total mortality at 6, 12, and 24 months was 3%, 11%, and 19% respectively. Only one patient had sudden cardiac death, occurring at 13 months postimplant. Overall, the non-thoracotomy lead system for this ICD displayed infrequent implant complications and proved to be reliable at terminating arrhythmias and maintaining a low rate of sudden cardiac death in this high risk population.Keywords
This publication has 8 references indexed in Scilit:
- Implantable transvenous cardioverter-defibrillators.Circulation, 1993
- Surgical experience with defibrillator implantation using nonthoracotomy leadsThe Annals of Thoracic Surgery, 1993
- Radiofrequency Catheter Ablation of the AV Node to Improve the Function of an Antitachycardia Implantable DefibrillatorPacing and Clinical Electrophysiology, 1992
- Failure of an implantable cardioverter-defibrillator to redetect ventricular fibrillation in patients with a nonthoracotomy lead system.Circulation, 1992
- Automatic implantable cardioverter-defibrillator implantation without thoracotomy using an endocardial and submuscular patch systemJournal of the American College of Cardiology, 1991
- Clinical experience in seventy-seven patients with the automatic implantable cardioverter defibrillatorAmerican Heart Journal, 1989
- Long-term outcome with the automatic implantable cardioverter-defibrillatorJournal of the American College of Cardiology, 1989
- Out-of-Hospital Cardiac ArrestNew England Journal of Medicine, 1988