Diagnostic Accuracy of Compression Ultrasonography for the Detection of Asymptomatic Deep Venous Thrombosis in Medical Patients

Abstract
We assessed the accuracy of venous compression ultrasonography (CUS) for the detection of asymptomatic deep vein thrombosis in 122 consecutive patients, with a mean age of 69 years, who were hospitalised in an internal medicine unit. All included patients had CUS within 48 h of admission. Twelve out of 17 patients with a positive CUS underwent phlebography, as the others withdrew their consent, whereas the remaining 105 patients with a negative serial CUS testing were clinically followed-up at 3 months. We found that CUS had a sensitivity and a specificity of respectively 1 (95% CI, 0.73 to 1) and 1 (95% CI, 0.96 to 1) for the detection of asymptomatic deep vein thrombosis. Kappa-coefficients for intra-observer and inter-observer agreements were respectively 0.88 and 0.56. We concluded that venous compression ultrasonography, performed as described, fulfils requirements of a screening test that could be available for prophylactic clinical trials or epidemiological researches.