Determination of blood lead using a 4{middle dot}0 mm paper punched disc carbon sampling cup technique
Open Access
- 1 July 1974
- journal article
- research article
- Published by BMJ in Occupational and Environmental Medicine
- Vol. 31 (3) , 239-244
- https://doi.org/10.1136/oem.31.3.239
Abstract
Cernik, A. A. (1974).British Journal of Industrial Medicine,31, 239-244. Determination of blood lead using a 4·0 mm paper punched disc carbon sampling cup technique. The method described is designed to overcome difficulties associated with presentation of the sample and its analysis for lead in blood. Chromium-51 studies on the effect of spread showed that imprecision resulted when discs of less than 4·0 mm diameter were punched from a given blood spot. The best standard deviation and relative standard deviation for increasing lead concentrations was obtained when 4·0 mm discs were used. Small daily voltage variations to the carbon cup workhead required that the non-specific absorption should be controlled to 0·02 absorbance at the ashing step. The occurrence of a second non-atomic signal was not considered significant since it had a different volatilization temperature to lead. Several advantages of the method are stated. A comparison of 4·0 mm against 6·5 mm punched discs was investigated using 33 samples of blood ranging from 9·0 to 126 μg of lead per 100 ml blood. Correlation (r = 0·970) and regression lines are shown. Absolute sensitivity of the method was 25 × 10-12 g.Keywords
This publication has 10 references indexed in Scilit:
- Decay of atom populations following graphite rod atomization in atomic absorption spectrometryAnalytical Chemistry, 1973
- The microdetermination of blood lead in children by flameless atomic absorption: the carbon rod atomizer.1972
- Carbon Rod Atomizer Applied to Measurement of Lead in Whole Blood by Atomic Absorption SpectrophotometryClinical Chemistry, 1972
- Determination of lead in capillary blood using a paper punched disc atomic absorption technique: Application to the supervision of lead workersOccupational and Environmental Medicine, 1971
- Biological applications of the carbon rod atomizer in atomic absorption spectroscopy. 1. Preliminary studies on magnesium, iron, copper, lead, and zinc in blood and plasma.1971
- Biological Applications of the Carbon Rod Atomizer in Atomic Absorption SpectroscopyClinical Chemistry, 1971
- Carbon rod atomizer in atomic absorption and fluorescence spectrometry and its clinical applicationAnalytical Chemistry, 1971
- The application of non-flame atom cells in atomic-absorption and atomic-fluorescence spectroscopy. A reviewThe Analyst, 1971
- A micro-sampling method for the rapid determination of lead in blood by atomic-absorption spectrophotometryThe Analyst, 1970