Quantification in tissue near–infrared spectroscopy
Open Access
- 29 June 1997
- journal article
- Published by The Royal Society in Philosophical Transactions Of The Royal Society B-Biological Sciences
- Vol. 352 (1354) , 649-659
- https://doi.org/10.1098/rstb.1997.0046
Abstract
In near–infrared spectroscopy (NIRS) of tissue, light attenuation is due to: (i) absorption from chromophores of fixed concentration, (ii) absorption from chromophores of variable concentration, and (iii) light scatter. NIRS is usually concerned with trying to quantify the concentrations of chromophores in category (ii), in particular oxy– and deoxyhaemoglobin (HbO2and Hb) and cytochrome oxidase.In the absence of scatter the total light absorption in the medium is a linear sum of that due to each chromophore. In a scattering medium like tissue, this linear summation is distorted because the optical path length at each wavelength may differ. This distorted spectrum is then superimposed upon a further wavelength–dependent attenuation arising from light loss due to scatter, which is a complex function of the tissue absorption and scattering coefficients (μaandμs), scattering phase function, and tissue and measurement geometry. Consequently, quantification of NIRS data is difficult.Over the past 20 years many differing approaches to quantification have been tried. The development of methods for measuring optical path length in tissue initially enabled changes in concentration to be quantified, and subsequently methods for absolute quantification of HbO2and Hb were developed by correlating NIRS changes with an independent measurement of arterial haemoglobin saturation. Absolute determination of tissue optical properties, however, requires additional information over and above the detected intensity at the tissue surface, which must then be combined with a model of light transport to deriveμaandμs. The additional data can take many forms, e.g. the change in intensity with distance, the temporal dispersion of light from an ultrashort input light pulse, or phase, and modulation depth changes of intensity–modulated light. All these approaches are now being actively pursued with considerable success. However, all the approaches are limited by the accuracy of the light transport models, especially in inhomogeneous media.Keywords
This publication has 10 references indexed in Scilit:
- The Noninvasive Measurement of Absolute Cerebral Deoxyhemoglobin Concentration and Mean Optical Path Length in the Neonatal Brain by Second Derivative Near Infrared SpectroscopyPediatric Research, 1996
- Determination of reduced scattering and absorption coefficients by a single charge-coupled-device array measurement, part I: comparison between experiments and simulationsOptical Engineering, 1995
- The theoretical basis for the determination of optical pathlengths in tissue: temporal and frequency analysisPhysics in Medicine & Biology, 1992
- Phase modulation system for dual wavelength difference spectroscopy of hemoglobin deoxygenation in tissuesPublished by SPIE-Intl Soc Optical Eng ,1990
- A review of the optical properties of biological tissuesIEEE Journal of Quantum Electronics, 1990
- A CCD Spectrophotometer to Quantitate the Concentration of Chromophores in Living Tissue Utilising the Absorption Peak of Water at 975 nmPublished by Springer Nature ,1989
- Time-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscleAnalytical Biochemistry, 1988
- Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain.Proceedings of the National Academy of Sciences, 1988
- System for long-term measurement of cerebral blood and tissue oxygenation on newborn infants by near infra-red transilluminationMedical & Biological Engineering & Computing, 1988
- Noninvasive Monitoring of Cerebral Oxygenation in Preterm Infants: Preliminary ObservationsPediatrics, 1985