Hemodynamic Effects of Cardiac Glycosides on Normal Human Subjects During Rest and Exercise
- 1 November 1958
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 13 (3) , 417-421
- https://doi.org/10.1152/jappl.1958.13.3.417
Abstract
The effect of digitalis on the rest and exercise hemodynamics of eight normal subjects was studied. Cardiac output was determined by the dye dilution technique, using a cuvette densitometer. Arterial and venous pressures were measured on Statham strain gauges. Data were obtained during rest and exercise before and after intravenous administration of 1.0–1.2 mg of digoxin or 1.6–1.8 mg of acetyl strophanthidin. At rest there was a decrease of cardiac output (average 12%), pulse rate (5%) and stroke volume (9%) and an average rise of blood pressure from 129/73 mm Hg (mean 95 mm Hg) to 156/86 mm Hg (mean 109 mm Hg) following digitalization. During exercise there was a decrease of cardiac output (average 18%), pulse rate (6%) and stroke volume (9%), but no change of blood pressure after digitalization. The systemic vascular resistance was increased following digitalization, both during rest and exercise. In three additional subjects, the blood pressure rise accompanying digitalization at rest was verified by demonstrating a prompt increase in blood pressure as acetyl strophanthidin was injected and a fall as the control saline injection was resumed. Since the positive inotropic action of digitalis explained neither the rise of systemic vascular resistance nor the fall of cardiac output following digitalization of normal subjects, a peripheral action of cardiac glycosides was suggested. It is concluded that whatever augmentation of myocardial contractility that may result from digitalization of the resting or exercising normal subject is overshadowed by the peripheral action of the drug. Submitted on May 29, 1958Keywords
This publication has 7 references indexed in Scilit:
- THE CARDIAC OUTPUT OF NORMAL SUBJECTS DETERMINED BY THE DYE-INJECTION METHOD AT REST AND DURING EXERCISEThe Lancet Healthy Longevity, 1954
- Ventricular FunctionCirculation, 1954
- Evaluation of a New Cuvette Densitometer for Determination of Cardiac OutputCirculation Research, 1953
- CARDIORESPIRATORY RESPONSES AND ELECTROCARDIOGRAPHIC CHANGES DURING EXERCISE BEFORE AND AFTER INTRAVENOUS DIGOXIN IN NORMAL SUBJECTSThe Lancet Healthy Longevity, 1952
- Some Effects of Digoxin on the Heart and Circulation in ManCirculation, 1951
- COMPARISON OF THE FICK AND DYE INJECTION METHODS OF MEASURING THE CARDIAC OUTPUT IN MANAmerican Journal of Physiology-Legacy Content, 1948
- STUDIES ON THE EFFECT OF THE ACTION OF DIGITALIS ON THE OUTPUT OF BLOOD FROM THE HEART. III. 12Journal of Clinical Investigation, 1932