Spirometry in the Lung Health Study: 1. Methods and Quality Control
- 1 June 1991
- journal article
- clinical trial
- Published by American Thoracic Society in American Review of Respiratory Disease
- Vol. 143 (6) , 1215-1223
- https://doi.org/10.1164/ajrccm/143.6.1215
Abstract
The Lung Health Study is a randomized clinical trial designed to determine whether a smoking intervention program and prescription of an inhaled bronchodilator can reduce the annual rate of decline of FEV1 (FEV1 slope) in cigarette smokers with mild to moderate airflow limitation. During the recruitment period, spirometry measurements were obtained during three screening visits from 5,887 cigarette smokers 35 to 60 yr of age. To improve the statistical power of the study to detect significant differences in the FEV1 slopes among study groups, the spirometry testing protocol carefully controls for multiple factors that are known to increase intraindividual variability of FEV1 and FVC results. These factors include participant preparation, maneuver acceptability and reproducibility, technician training and performance monitoring, equipment design and calibration, and result processing. The objective of this report is to describe the success of the spirometry quality control program in minimizing the short-term intraindividual FEV1 variability. The mean difference between the FEV1 values obtained at the second and third screening visits (mean 25 days apart) was +5.7 ml in women and -14.7 ml in men, with a mean intraindividual variability of 119 ml in women and 162 ml in men, with a coefficient of variation of 5.8% for both. During only 2.1% of the test sessions were participants unable to produce three acceptable FVC maneuvers with the two best FEV1 values matching within 5% or 100 ml. Institution of site visits and technician performance monitoring was associated with improved test session quality grades and maintenance of high quality grades thereafter.Keywords
This publication has 12 references indexed in Scilit:
- Performance Evaluation of Contemporary SpirometersChest, 1990
- Estimation of the coefficient of variation from laboratory analysis of split specimens for quality control in clinical trialsControlled Clinical Trials, 1990
- Effect of Effort on Measurement of Forced Expiratory Volume in One SecondAmerican Review of Respiratory Disease, 1987
- Longitudinal Changes in Forced Expiratory Volume in One Second in AdultsAmerican Review of Respiratory Disease, 1987
- Influence of cigarette smoking on lung function at baseline and at follow-up in 14 years: The Framingham StudyJournal of Chronic Diseases, 1987
- Methodologic issues in the analysis of lung function dataJournal of Chronic Diseases, 1987
- A computer system for analysis and transmission of spirometry waveforms using volume samplingComputers and Biomedical Research, 1984
- Spirometry: what paper speed?Chest, 1983
- Assessment of respiratory function in patients with chronic obstructive airways disease.Thorax, 1979
- Spirometry using motivational techniquesJournal of Chronic Diseases, 1971