Evaluation of the BD Vacutainer® PST™ II Blood Collection Tube for special chemistry analytes
- 1 January 2009
- journal article
- research article
- Published by Walter de Gruyter GmbH in cclm
- Vol. 47 (3) , 358-61
- https://doi.org/10.1515/cclm.2009.072
Abstract
: The performance of the BD Vacutainer: Tubes were drawn by routine venipuncture from 42 subjects according to a randomized draw order. Tubes were processed and centrifuged according to recommended handling procedures. Serum and plasma from the comparison tubes were aliquoted to secondary containers prior to analysis. Specimens were then tested for selected special chemistry analytes at two time intervals (initial time and after 24 h storage). Analytes tested included thyroid stimulating hormone, free thyroxine, total thyroxine, follicle stimulating hormone, luteinizing hormone, ferritin, cortisol, vitamin B12, folate, and testosterone. The data were collected and analyzed by analysis of variance and mean bias comparisons.: The performance of the BD Vacutainer: The BD VacutainerClin Chem Lab Med 2009;47:358–61.Keywords
This publication has 17 references indexed in Scilit:
- Comparison of Bayer Advia Centaur® immunoassay results obtained on samples collected in four different Becton Dickinson Vacutainer® tubesAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 2006
- Comparison of Serum and Heparinized Plasma Samples for Measurement of Chemistry AnalytesClinical Chemistry, 2004
- Plasma or serum samples: measurements of cardiac troponin T and of other analytes comparedcclm, 2004
- Reliability of IFCC Method for Lactate Dehydrogenase Measurement in Lithium-Heparin Plasma SamplesClinical Chemistry, 2003
- Effect of anticoagulants and storage temperatures on stability of plasma and serum hormonesPublished by Elsevier ,2001
- Lower Cardiac Troponin T and I Results in Heparin-Plasma Than in SerumClinical Chemistry, 2000
- Troponin T and I Assays Show Decreased Concentrations in Heparin Plasma Compared with Serum: Lower Recoveries in Early than in Late Phases of Myocardial InjuryClinical Chemistry, 2000
- Effect on 16 Analytes of Overnight Storage of Specimens Collected into Heparinised Evacuated Tubes with Plasma SeparatorAnnals of Clinical Biochemistry: International Journal of Laboratory Medicine, 1990
- Serum and plasma compared for use in 19 common chemical tests performed in the Hitachi 737 analyzer.Clinical Chemistry, 1989
- A Comparison of Results for Serum Versus Heparinized Plasma for 30 Common AnalytesLaboratory Medicine, 1987