Pulmonary Metastases: Effect of CT Section Thickness on Measurement—Initial Experience
- 1 March 2005
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 234 (3) , 934-939
- https://doi.org/10.1148/radiol.2343040020
Abstract
PURPOSE: To assess the effect of commonly used computed tomographic (CT) section thicknesses on metastatic tumor measurements calculated with unidimensional, bidimensional, area, and volumetric methods. MATERIALS AND METHODS: Analysis and data collection were approved by the Institutional Review Board, with waived informed patient consent. Forty-two pulmonary metastases in 10 patients (three men and seven women; age range, 43-83 years; mean age, 65.4 years) were analyzed on CT scans obtained with 3.75-, 5.0-, and 7.5-mm section thicknesses. The lesions were automatically delineated by using a three-dimensional multicriteria segmentation algorithm. Unidimensional (the largest diameter), bidimensional (the product of the two maximal perpendicular diameters), maximal cross-sectional area, and Volumetric measurements were automatically obtained for each pulmonary lesion on each section thickness. Means and variances were calculated, and the differences across the three section thicknesses for each of the four measurements were studied by using linear mixed-effects models. The Levene test was used to study the equality of variances. RESULTS: Differences in the means for unidimensional, bidimensional, and area measurements were significant between a section thickness of 3.75 and 5.0 mm (unidimensional, P = .05; bidimensional, P = .05; area, P = .01) and 3.75 and 7.5 mm (unidimensional, P = .06; bidimensional, P = .03; area, P = .02), but not 5.0 and 7.5 mm. There was a significant difference in volumetric measurement as section thickness decreased from 7.5 to 5.0 mm (P < .001) and from 7.5 to 3.75 mm (P < .001). Although there was a slight trend for differences in the variances across section thickness for each measurement, none of the differences were significant. CONCLUSION: Volumetric tumor measurements change with a reduction in section thickness from 7.5 to 5.0 and 3.75 mm. For unidimensional measurement, no change was found when thickness decreased from 7.5 to 5.0 mm. (C) RSNA, 2005.This publication has 21 references indexed in Scilit:
- Radiologic Measurement of Tumor Size in Clinical TrialsAmerican Journal of Roentgenology, 2001
- Generalized, Linear, and Mixed ModelsWiley Series in Probability and Statistics, 2000
- New Guidelines to Evaluate the Response to Treatment in Solid TumorsJNCI Journal of the National Cancer Institute, 2000
- Three-dimensional multicriterion automatic segmentation of pulmonary nodules of helical computed tomography imagesOptical Engineering, 1999
- Two‐dimensional multi‐criterion segmentation of pulmonary nodules on helical CT imagesMedical Physics, 1999
- Consistent segmentation of repeat CT scans for growth assessment in pulmonary nodulesPublished by SPIE-Intl Soc Optical Eng ,1999
- Three-dimensional quantitation of pediatric tumor bulkPediatric Radiology, 1995
- Southwest Oncology Group standard response criteria, endpoint definitions and toxicity criteriaInvestigational New Drugs, 1992
- What does "response" in cancer chemotherapy really mean?BMJ, 1981
- Reporting results of cancer treatmentCancer, 1981