Effect of Voltage Recovery Rates on Interrupting Performance of Air-Blast Circuit Breakers [includes discussion]
- 1 April 1953
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems
- Vol. 72 (2) , 303-311
- https://doi.org/10.1109/aieepas.1953.4498637
Abstract
Recovery rate is the term applied to the rate at which voltage rises across a circuit breaker immediately following interruption. Before high-voltage air-blast circuit breakers can be economically applied, a thorough knowledge of the relationships between circuit-breaker duties and recovery rates on systems is necessary. Whereas the performance of the modern oil circuit breaker is relatively unaffected by circuit recovery rate, the authors have found that this factor has a very significant effect on the performance of the radial-type air-blast circuit breaker. Using the minimum pressure required to produce successful interruption as a measure of circuit severity on the circuit breaker, an empirical relationship correlating the influence of both current and recovery rates has been found. As shown by this relationship, reduction of the inherent recovery rates by using linear resistors may be desirable in those circuits possessing unusually high rates. Until the relationships between system recovery rates and circuit-breaker duties have been correlated, it is advisable to apply these circuit breakers only where these factors and the circuit-breaker characteristics are both understood.Keywords
This publication has 8 references indexed in Scilit:
- Switching Equipment for New Switchgear Development Laboratory [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1953
- Consideration in Testing, Rating, and Application of Power Circuit Breakers [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1952
- Out-of-phase switching voltages and their effect on high-voltage circuit breaker performance [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1952
- The Effect of Current Asymmetry on Circuit Interruption [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1952
- Considerations in the Rating and Testing of Power Circuit Breakers [includes discussion]Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems, 1952
- A New 69-Kv Air Blast Circuit BreakerTransactions of the American Institute of Electrical Engineers, 1951
- Transient Recovery-Voltage Characteristics of Electric-Power SystemsTransactions of the American Institute of Electrical Engineers, 1942
- Tests on General Electric Oil Circuit Breakers at BaltimoreTransactions of the American Institute of Electrical Engineers, 1922