Randomized, Clinical Trial Comparison of Trisodium Citrate 30% and Heparin as Catheter-Locking Solution in Hemodialysis Patients
Top Cited Papers
- 1 September 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of the American Society of Nephrology
- Vol. 16 (9) , 2769-2777
- https://doi.org/10.1681/asn.2004100870
Abstract
Interdialytic hemodialysis catheter-locking solutions could contribute to a reduction of catheter-related complications, especially infections. However, they can cause side effects because of leakage from the tip of the catheter. Recently, trisodium citrate (TSC) has been advocated because of its antimicrobial properties and local anticoagulation. In a multicenter, double-blind, randomized, controlled trial, TSC 30% was compared with unfractionated heparin 5000 U/ml for prevention of catheter-related infections, thrombosis, and bleeding complications. The study was stopped prematurely because of a difference in catheter-related bacteremia (CRB; P < 0.01). Of 363 eligible patients, 291 could be randomized. The study included 98 tunneled cuffed catheters and 193 untunneled. There were no significant differences in patient and catheter characteristics on inclusion. In the heparin group, 46% of catheters had to be removed because of any complication compared with 28% in the TSC group (P = 0.005). CRB rates were 1.1 per 1000 catheter-days for TSC versus 4.1 in the heparin group (P < 0.001). For tunneled cuffed catheters, the risk reduction for CRB was 87% (P < 0.001) and for untunneled catheters was 64% (P = 0.05). Fewer patients died from CRB in the TSC group (0 versus 5; P = 0.028). There were no differences in catheter flow problems and thrombosis (P = 0.75). No serious adverse events were encountered. Major bleeding episodes were significantly lower in the TSC group (P = 0.010). TSC 30% improves overall patency rates and reduces catheter-related infections and major bleeding episodes for both tunneled and untunneled hemodialysis catheters. Flow problems are not reduced.Keywords
This publication has 31 references indexed in Scilit:
- Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solutionNephrology Dialysis Transplantation, 2004
- Multicenter clinical trial results with the LifeSite® hemodialysis access systemKidney International, 2002
- Vascular access use in Europe and the United States: Results from the DOPPSKidney International, 2002
- Temporary Vascular Access for Hemodialysis TreatmentPublished by S. Karger AG ,2002
- A prospective study of complications associated with cuffed, tunnelled haemodialysis catheters†Nephrology Dialysis Transplantation, 2001
- Risk of heparin lock‐related bleeding when using indwelling venous catheter in haemodialysisNephrology Dialysis Transplantation, 2001
- III. NKF-K/DOQI Clinical Practice Guidelines for Vascular Access: Update 2000American Journal of Kidney Diseases, 2001
- Risk of bacteremia from temporary hemodialysis catheters by site of insertion and duration of use: A prospective studyKidney International, 2000
- Bacteremia associated with tunneled, cuffed hemodialysis cathetersAmerican Journal of Kidney Diseases, 1999
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958