Prediction of transient performance of isolated saturated synchronous generator
- 1 January 1972
- journal article
- Published by Institution of Engineering and Technology (IET) in Proceedings of the Institution of Electrical Engineers
- Vol. 119 (9) , 1309-1318
- https://doi.org/10.1049/piee.1972.0259
Abstract
The paper describes a digital simulation of a 3-phase model of a synchronous generator, directly in phase quantities. It is shown how, on the assumption that saturation arises principally from the resultant direct-axis current, the corresponding nonlinearities may be included in the equations of the model. The equations are developed in a form suitable for the study of both symmetrical and asymmetrical operating conditions of an isolated machine, and a digital-computer program using predictor-corrector techniques is described for their solution. Predictions of the transient conditions following a variety of switching operations are shown to compare closely with experimentally obtained results on a 15 kV A machine.Keywords
This publication has 0 references indexed in Scilit: