The precision of proton range calculations in proton radiotherapy treatment planning: experimental verification of the relation between CT-HU and proton stopping power
- 1 June 1998
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 43 (6) , 1579-1592
- https://doi.org/10.1088/0031-9155/43/6/016
Abstract
The precision in proton radiotherapy treatment planning depends on the accuracy of the information used to calculate the stopping power properties of the tissues in the patient's body. This information is obtained from computed tomography (CT) images using a calibration curve to convert CT Hounsfield units into relative proton stopping power values. The validity of a stoichiometric method to create the calibration curve has been verified by measuring pairs of Hounsfield units and stopping power values for animal tissue samples. It was found that the agreement between measurement and calibration curve is better than 1% if beam hardening effects in the acquisition of the CT images can be neglected. The influence of beam hardening effects on the quantitative reading of the CT measurements is discussed and an estimation for the overall range precision of proton beams is given. It is expected that the range of protons in the human body can be controlled to better than of the water equivalent range in soft tissue and in bone, which translates into a range precision of about 1-3 mm in typical treatment situations.Keywords
This publication has 12 references indexed in Scilit:
- X-ray attenuation coefficients of elements and mixturesPublished by Elsevier ,2002
- The calibration of CT Hounsfield units for radiotherapy treatment planningPhysics in Medicine & Biology, 1996
- Proton radiography as a tool for quality control in proton therapyMedical Physics, 1995
- An electron density calibration phantom for CT-based treatment planning computersMedical Physics, 1992
- Acceptance testing computerized radiation therapy treatment planning systems: Direct utilization of CT scan dataMedical Physics, 1985
- Energy loss, range, path length, time-of-flight, straggling, multiple scattering, and nuclear interaction probabilityAtomic Data and Nuclear Data Tables, 1982
- Computed tomography using proton energy lossPhysics in Medicine & Biology, 1981
- Compton scatter imaging of transverse sections: an overall appraisal and evaluation for radiotherapy planningPhysics in Medicine & Biology, 1981
- Dosimetric Evaluation of a Computed Tomography Treatment SystemRadiology, 1979
- Measurement of effective atomic number and electron density using an EMI scannerNeuroradiology, 1976