Automatic removal of the eye blink artifact from EEG using an ICA-based template matching approach
- 14 March 2006
- journal article
- Published by IOP Publishing in Physiological Measurement
- Vol. 27 (4) , 425-436
- https://doi.org/10.1088/0967-3334/27/4/008
Abstract
Independent component analysis (ICA) proves to be effective in the removing the ocular artifact from electroencephalogram recordings (EEG). While using ICA in ocular artifact correction, a crucial step is to correctly identify the artifact components among the decomposed independent components. In most previous works, this step of selecting the artifact components was manually implemented, which is time consuming and inconvenient when dealing with a large amount of EEG data. We present a new method which automatically selects the eye blink artifact components based on the pattern of their scalp topographies, which can be exemplified as a template matching approach. The feasibility of using a fixed template for singling out the eye blink component after ICA decomposition was validated by an experiment in which 18 subjects among the 21 subjects involved exhibited a highly consistent pattern of eye blink scalp topographies. Since only the spatial feature is employed for singling out the eye blink component, the proposed method is very efficient and easy to implement. Objective evaluation of the real results shows that the proposed algorithm can remove the eye blink artifact from the EEG while causing little distortion to the underlying brain activities.Keywords
This publication has 10 references indexed in Scilit:
- Artifact removal from electroencephalograms using a hybrid BSS-SVM algorithmIEEE Signal Processing Letters, 2005
- Automatic removal of eye movement and blink artifacts from EEG data using blind component separationPsychophysiology, 2003
- A new method for off-line removal of ocular artifactPublished by Elsevier ,2003
- Removal of eye activity artifacts from visual event-related potentials in normal and clinical subjectsPublished by Elsevier ,2000
- Removing electroencephalographic artifacts by blind source separationPsychophysiology, 2000
- Removal of ocular artifact from the EEG: a reviewNeurophysiologie Clinique, 2000
- EOG correction: Which regression should we use?Psychophysiology, 2000
- Independent Component Analysis Using an Extended Infomax Algorithm for Mixed Subgaussian and Supergaussian SourcesNeural Computation, 1999
- An Information-Maximization Approach to Blind Separation and Blind DeconvolutionNeural Computation, 1995
- Ocular artifacts in EEG and event-related potentials I: Scalp topographyBrain Topography, 1993