201Tl-labelled T1C1 dosimetry revisited
- 1 February 1993
- journal article
- review article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 14 (2) , 104-107
- https://doi.org/10.1097/00006231-199302000-00005
Abstract
A review of the literature pertaining to the human dosimetry of 201Tl-labelled thallous chloride provides a spectrum of organ absorbed doses associated with this radiopharmaceutical. A more recent article details human quantitative studies up to 216 h postadministration. This multiorgan radiopharmacological study, however, reports the kidney dosimetry to be significantly lower than previous values; 0.0647 mGy MBq1 (0.238 rad mCi-1) compared to 0.326 mGy MBq-1 (1.2 rad mCi-1). Because of the latter discrepancy the dosimetry was recalculated using the reported pharmacodynamic data. This recalculation resulted in a kidney radiation dose comparable to previously published reports of 0.514 mGy MBq-1 (1.89 rad mCi-1). Also, revised absorbed doses to the various segments of the gastrointestinal tract (GIT) were significantly higher.Keywords