A proof that uniform dose gives the greatest TCP for fixed integral dose in the planning target volume
- 1 November 1994
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 39 (11) , 2091-2098
- https://doi.org/10.1088/0031-9155/39/11/018
Abstract
In this note it is shown that for a fixed integral dose to the planning target volume, the highest tumour control probability (TCP) arises when the dose is spatially uniform. This 'uniform dose theorem' is proved both for (i) a specific TCP model based on Poisson/independent voxel statistics, and (ii) any model for voxel control probability having a specific shape with respect to increasing dose.Keywords
This publication has 3 references indexed in Scilit:
- A model for calculating tumour control probability in radiotherapy including the effects of inhomogeneous distributions of dose and clonogenic cell densityPhysics in Medicine & Biology, 1993
- Clinical implications of heterogeneity of tumor response to radiation therapyRadiotherapy and Oncology, 1992
- Dosimetric Precision Requirements in Radiation TherapyActa Radiologica: Oncology, 1984