An in-vitro morphological study of Q-switched neodymium/YAG laser trabeculotomy.
Open Access
- 1 February 1986
- journal article
- research article
- Published by BMJ in British Journal of Ophthalmology
- Vol. 70 (2) , 89-96
- https://doi.org/10.1136/bjo.70.2.89
Abstract
Laser trabeculotomies produced by directing a pulsed neodymium/YAG laser beam at specimens of human anterior chamber angle obtained post mortem or after enucleation were studied by light microscopy and by scanning and transmission electron microscopy to assess the dimensions of the openings created in the trabecular meshwork, their penetrance to the canal of Schlemm, and the extent or absence of laser induced cellular damage in immediately adjacent tissue. A pulse duration of 40-50 ns at energy levels of around 30 mJ was used and the laser cavity carefully tuned to give a Gaussian spatial mode pattern. Openings in the trabecular meshwork typically of 100 microns in diameter and penetrating through to the canal of Schlemm could be regularly created with only minimal damage to adjacent tissue as judged by transmission electron microscopy. The information so gained may be useful in determining the parameters required for successful laser trabeculotomy as a treatment for primary open-angle glaucoma.This publication has 11 references indexed in Scilit:
- In vitro studies with a pulsed neodymium/YAG laser.British Journal of Ophthalmology, 1985
- Lasers in the treatment of chronic simple glaucoma.1982
- Electron Microscopy of Argon Laser Therapy in Phakic Open-angle GlaucomaOphthalmology, 1982
- ARGON LASER TREATMENT OF THE ANTERIOR CHAMBER ANGLE FOR INCREASED INTRAOCULAR PRESSUREActa Ophthalmologica, 1981
- Long-Term Control of Adult Open Angle Glaucoma by Argon Laser TreatmentOphthalmology, 1981
- Argon Laser Trabecular Surgery in Uncontrolled Phakic Open Angle GlaucomaOphthalmology, 1981
- Laser Therapy for Open Angle GlaucomaOphthalmology, 1981
- Argon Laser Therapy for Open-Angle GlaucomaArchives of Ophthalmology (1950), 1979
- Laser-induced electric breakdown in solidsIEEE Journal of Quantum Electronics, 1974
- [Laser puncture of the anterior chamber angle in glaucoma (a preliminary report)].1972