Use of an Enzyme Immunoassay Does Not Eliminate the Need To Analyze Multiple Stool Specimens for Sensitive Detection of Giardia lamblia
Open Access
- 1 February 2001
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 39 (2) , 474-477
- https://doi.org/10.1128/jcm.39.2.474-477.2001
Abstract
The relative sensitivities of a commercially available enzyme immunoassay (EIA) (ProSpecT Giardia; Alexon-Trend Inc., Ramsey, Minn.) and conventional ovum-and-parasite (O&P) examination for the detection of Giardia lamblia in preserved stool specimens were determined. Paired stool samples collected independently within a 7-day period from 103 patients were analyzed by both methods. A total of 54 specimens from 30 patients (18 asymptomatically infected with G. lamblia and 12 with symptoms consistent with intestinal giardiasis) were determined to be positive for G. lamblia, of which 48 (88.9%) were positive by microscopy and 52 (96.3%) were positive by EIA. Both specimens submitted were positive for G. lamblia by O&P examination for 66.7% (20 of 30) of the positive patients; for 26.7% (8 of 30) a single specimen was positive by O&P examination, and for 6.7% (2 of 30) of those determined to be infected with G. lamblia, both samples were negative by microscopy. The sensitivity of conventional O&P examination was somewhat higher in symptomatically infected individuals, with 75% (9 of 12) of patients in this category havingG. lamblia detected in both samples, compared with 61% (11 of 18) of asymptomatic patients. A total of 24 positive patients (80%) had G. lamblia antigen detected by EIA in both submitted samples, 4 positive patients (13.3%) had one specimen positive by EIA, and the EIA was negative in both specimens from 2 infected individuals (6.5%), the sensitivity of EIA was substantially equivalent in asymptomatic and symptomatic individuals (77 versus 83% of patients with positive results on both specimens). Although the sensitivity of EIA for the detection of G. lamblia on a single stool specimen was somewhat higher than that of conventional O&P examination in symptomatic patients (83 versus 75%), in asymptomatic patients (77 versus 61%), and overall (80 versus 67%), examination of two specimens by either EIA or microscopy was necessary to achieve a diagnostic sensitivity of greater than 90%.Keywords
This publication has 18 references indexed in Scilit:
- Comparison of Nine Commercially Available Enzyme-Linked Immunosorbent Assays for Detection of Giardia lamblia in Fecal SpecimensJournal of Clinical Microbiology, 1998
- Sensitivity of microscopy versus enzyme immunoassay in the laboratory diagnosis of giardiasisEuropean Journal of Clinical Microbiology & Infectious Diseases, 1997
- Evaluation of nine immunoassay kits (enzyme immunoassay and direct fluorescence) for detection of Giardia lamblia and Cryptosporidium parvum in human fecal specimensJournal of Clinical Microbiology, 1997
- Comparison of conventional stool concentration and preserved-smear methods with Merifluor Cryptosporidium/Giardia Direct Immunofluorescence Assay and ProSpecT Giardia EZ Microplate Assay for detection of Giardia lambliaJournal of Clinical Microbiology, 1995
- Evaluation of a commercially available ELISA assay for detection of Giardia lamblia in fecal specimensDiagnostic Microbiology and Infectious Disease, 1995
- Evaluation of rapid commercial enzyme immunoassay for detection of Giardia lamblia in formalin-preserved stool specimensJournal of Clinical Microbiology, 1994
- Application of rejection criteria for stool ovum and parasite examinationsJournal of Clinical Microbiology, 1992
- Stool diagnosis of giardiasis using a commercially available enzyme immunoassay to detect Giardia-specific antigen 65 (GSA 65)Journal of Clinical Microbiology, 1989
- Numbers of Giardia in the Feces of Infected ChildrenThe American Journal of Tropical Medicine and Hygiene, 1975
- A Rapid Staining Procedure for Intestinal Amoebae and Flagellates*American Journal of Clinical Pathology, 1951