Mechanical loading thresholds for lamellar and woven bone formation
- 1 January 1994
- journal article
- research article
- Published by Oxford University Press (OUP) in Journal of Bone and Mineral Research
- Vol. 9 (1) , 87-97
- https://doi.org/10.1002/jbmr.5650090113
Abstract
Bone formation was measured in rat tibiae after 12 days of applied loading. Bending forces were applied using a four‐point loading apparatus. Sham loads were applied at the same magnitudes as bending forces but the loading pads were arranged so that bending was minimized. Bending and sham loading were applied to the right tibiae of rats and the left tibiae served as contralateral controls. Loading was applied as a sine wave with a frequency of 2 Hz for 18 s (36 cycles) per day. The peak magnitude of applied load was 27, 33, 40, 52, and 64 N. Woven bone was observed on the periosteal surface in all animals subjected to loads of 40 N or greater. Periosteal woven bone formation occurred in both bending and sham loading groups. Woven bone formation on the periosteal surface was either absent or responded at a maximal rate if the stimulus threshold was surpassed. The amount of new woven bone and the woven bone‐forming surface were independent of the magnitude of applied strain. Bone formation on the endocortical surface was exclusively lamellar. Lamellar bone formation was stimulated by applied bending of the tibia but not by sham loading. Bending strains above a loading threshold of 40 N or about 1050 μstrain increased both bone‐forming surface and the mineral apposition rate and subsequently increased the bone formation rate as much as sixfold. No evidence of increased bone formation was seen for applied strains below 1050 μstrain. Examination of bulk stained sections from animals exposed to the highest applied loads showed no evidence of microcracks. Thus, microcracks have not been implicated as a causal factor for the observed increases in bone formation rate.Keywords
Funding Information
- Whitaker Foundation
- National Institutes of Health ((Grant AR40688))
- Australian National Health
- Medical Research Council
This publication has 20 references indexed in Scilit:
- Characterization of in vivo strain in the rat tibia during external application of a four-point bending loadJournal of Biomechanics, 1992
- A noninvasive, in vivo model for studying strain adaptive bone modelingBone, 1991
- Validity of the Bulk-Staining Technique to Separate Artifactual From In Vivo Bone MicrodamageClinical Orthopaedics and Related Research, 1990
- In vivo effects of human recombinant transforming growth factor β on bone turnover in normal miceJournal of Bone and Mineral Research, 1990
- Transforming growth factor-beta and the initiation of chondrogenesis and osteogenesis in the rat femur.The Journal of cell biology, 1990
- Stimulation of bone formation in vivo by transforming growth factor-β: Remodeling of woven bone and lack of inhibition by indomethacinBone, 1990
- Skeletal change in response to altered strain environments: Is woven bone a response to elevated strain?Bone, 1989
- Regulation of bone mass by mechanical strain magnitudeCalcified Tissue International, 1985
- Mechanically adaptive bone remodellingJournal of Biomechanics, 1982
- The influence of strain rate on adaptive bone remodellingJournal of Biomechanics, 1982