A Six-Port Reflectometer and its Complete Characterization by Convenient Calibration Procedures
- 1 February 1982
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 30 (2) , 186-192
- https://doi.org/10.1109/tmtt.1982.1131045
Abstract
A simple six-port reflectometer and two methods of calibration using either 51/2 or 61/2 standard terminations are described. High precision is obtained using diode detectors, which are calibrated in situ against a single thermistor power meter. The addition of a few extra components provides a moderately accurate visual display in real time over the 1-8-GHz band.Keywords
This publication has 9 references indexed in Scilit:
- Analysis and calibration theory of the general 6-port reflectometor employing four amplitude detectorsProceedings of the Institution of Electrical Engineers, 1979
- Calibrating the Six-Port Reflectometer by Means of Sliding TerminationsIEEE Transactions on Microwave Theory and Techniques, 1978
- The Six-Port Reflectometer: An Alternative Network AnalyzerIEEE Transactions on Microwave Theory and Techniques, 1977
- Automated measurement of noisy voltages with a preset confidence levelElectronics Letters, 1977
- Using six-port and eight-port junctions to measure active and passive circuit parametersPublished by National Institute of Standards and Technology (NIST) ,1975
- Calibration of an Arbitrary Six-Port Junction for Measurement of Active and Passive Circuit ParametersIEEE Transactions on Instrumentation and Measurement, 1973
- The Locating ReflectometerIEEE Transactions on Microwave Theory and Techniques, 1972
- Application of an Arbitrary 6-Port Junction to Power-Measurement ProblemsIEEE Transactions on Instrumentation and Measurement, 1972
- Microwave Reflectometer TechniquesIEEE Transactions on Microwave Theory and Techniques, 1959