Mechanical aspects of vascular graft-host artery anastomoses
- 1 August 1994
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Engineering in Medicine and Biology Magazine
- Vol. 13 (4) , 517-524
- https://doi.org/10.1109/51.310993
Abstract
For vascular graft implantation the mechanical stresses induced by abnormal flow dynamics as well as regions of stress concentration in the walls of the host artery and the graft appear to play an important role in neo-intimal fibrous hyperplasia formation and loss of patency. Detailed in vitro and in vivo experimental studies as well as theoretical analysis, will help delineate the factors responsible for hyperplasia formation and thus enable modifications in the design characteristics to minimize the problem. In the case of end-to-end anastomoses the compliance mismatch between the host artery and the vascular graft appears to be the dominant factor for the abnormal flow dynamics in the anastomotic region. However, in end-to-side anastomoses, the geometry at the anastomosis appears to be more important, with the compliance mismatch playing a secondary role. Further detailed experimental studies complemented by detailed three-dimensional unsteady flow analysis in realistic anastomotic geometries are needed to suggest possible solutions to minimize the problem of loss of patency, particularly with medium and small diameter vascular grafts.Keywords
This publication has 29 references indexed in Scilit:
- VEIN TO ARTERY GRAFTS: A MORPHOLOGICAL AND HISTOCHEMICAL STUDY OF THE HISTOGENESIS OF INTIMAL HYPERPLASIAAnz Journal of Surgery, 1992
- Myointimal thickening in experimental vein grafts is dependent on wall tensionJournal of Vascular Surgery, 1992
- The Effect of Angle and Flow Rate Upon Hemodynamics in Distal Vascular Graft Anastomoses: An In Vitro Model StudyJournal of Biomechanical Engineering, 1991
- Steady and pulsatile flow fields in an end-to-side arterial anastomosis modelJournal of Vascular Surgery, 1990
- Simulation study of the fluid dynamics of aorto-coronary bypassJournal of Biomedical Engineering, 1990
- Experimental determination of mechanical shear stress about an anastomotic junctionJournal of Biomechanics, 1987
- Finite analytic numerical method for unsteady two-dimensional Navier-Stokes equationsJournal of Computational Physics, 1984
- Polyester prostheses as substitutes in the thoracic aorta of dogs. I. Evaluation of commercial prosthesesJournal of Biomedical Materials Research, 1983
- A Mechanism of Failure in Dacron(r) Arterial GraftsAnnals of Surgery, 1983
- Effect of Healing on Small Internal Diameter Arterial Graft ComplianceBiomaterials, Medical Devices, and Artificial Organs, 1983